Hi,
I have an issue with asn2wrs.
In the ASN file, I have for example this definition:
correlationID [0] IMPLICIT OCTET STRING (SIZE(14))
This by default gets compiled into the following code:
{ &hf_ivrasn_correlationID,
{ "correlationID", "ivrasn.correlationID",
FT_BYTES, BASE_NONE, NULL, 0,
"OCTET_STRING_SIZE_14", HFILL }},
And of course when the data is displayed, the string is in hex.
I have added an entry in the conformance file, and the debug output of
the compiler shows the following :
# Conformance values
File Line Table Key Value
----------------------------------------------------------------------------------------------------
./myasn.cnf 11 PDU MessageType {'export':
False, 'new': False, 'hidden': False, 'need_decl':False, 'reg': None}
./myasn.cnf 131 TYPE_ATTR OCTET_STRING_SIZE_14 {'TYPE':
'FT_STRING', 'DISPLAY': 'BASE_NONE'}
./myasn.cnf 128 TYPE_ATTR correlationID {'TYPE':
'FT_STRING', 'DISPLAY': 'BASE_NONE'}
./myasn.cnf 127 TYPE_ATTR errorCode {'TYPE':
'FT_INT32', 'DISPLAY': 'BASE_DEC', 'STRINGS': 'VALS(errorCodeNames)'}
./myasn.cnf 126 TYPE_ATTR operationCode {'TYPE':
'FT_INT32', 'DISPLAY': 'BASE_DEC', 'STRINGS':
'VALS(myOperationNames)'}
./myasn.cnf 130 TYPE_ATTR uIScriptResult {'TYPE':
'FT_STRING', 'DISPLAY': 'BASE_NONE'}
./myasn.cnf 129 TYPE_ATTR uIScriptSpecificInformation
{'TYPE': 'FT_STRING', 'DISPLAY': 'BASE_NONE'}
However, it still does the default code generation, and the output is hex.
The generated code should be something like the following, so that the
dissector display is in ascii text:
{ &hf_myasn_correlationID,
{ "correlationID", "myasn.correlationID",
FT_STRING, BASE_NONE, NULL, 0,
"OCTET_STRING_SIZE_14", HFILL }},
So is there some other trick I may have missed?
Many thanks,
Risto