Wireshark-dev: Re: [Wireshark-dev] Request for Addition of UNISTIM CMD Address Text to Info Fie
Hi John,
Added your request to the TODO file in the unistim plugin directory.
Thanx,
Jaap
J P wrote:
Hi,
Would it be possible to add the UNISTIM CMD text for each UNISTIM
command in a packet to the Info field of the Decode Summary?
For example display the following for the UNISTIM commands shown below:
33 3.204370 x.x.x.x y.y.y.y UNISTIM Payload seq - 0xC469, Aggregate
Unistim , Display Manager Switch , Display Manager Switch .......
UNISTIM Protocol
Reliable UDP
RUDP Seq Num: Normal Sequence Number (0x0000c469)
RUDP Pkt type: Payload (2)
UNISTIM Payload: Aggregate Unistim (0x01)
Unistim CMD
UNISTIM CMD Address: Display Manager Switch (0x17)
UNISTIM CMD Length: 5
Display Cmd (switch): Clear Field (0x0f)
0001 0000 = FLAGS: For Following Byte
.... ...0 = Numeric Index Field in InfoBar: False
.... ..0. = Context Field in InfoBar: False
.... .0.. = Date Field: False
.... 0... = Time Field: False
...1 .... = Line Data: True
..0. .... = Status Bar Icon: False
.0.. .... = Soft Key: False
0... .... = Soft Key Label: False
0000 0001 = FLAGS: For Following Byte
.... ...1 = Line 1: True
.... ..0. = Line 2: False
.... .0.. = Line 3: False
.... 0... = Line 4: False
...0 .... = Line 5: False
..0. .... = Line 6: False
.0.. .... = Line 7: False
0... .... = Line 8: False
Unistim CMD
UNISTIM CMD Address: Display Manager Switch (0x17)
UNISTIM CMD Length: 5
Display Cmd (switch): Clear Field (0x0f)
0001 0000 = FLAGS: For Following Byte
.... ...0 = Numeric Index Field in InfoBar: False
.... ..0. = Context Field in InfoBar: False
.... .0.. = Date Field: False
.... 0... = Time Field: False
...1 .... = Line Data: True
..0. .... = Status Bar Icon: False
.0.. .... = Soft Key: False
0... .... = Soft Key Label: False
0000 0010 = FLAGS: For Following Byte
.... ...0 = Line 1: False
.... ..1. = Line 2: True
.... .0.. = Line 3: False
.... 0... = Line 4: False
...0 .... = Line 5: False
..0. .... = Line 6: False
.0.. .... = Line 7: False
0... .... = Line 8: False
Unistim CMD
UNISTIM CMD Address: Display Manager Switch (0x17)
UNISTIM CMD Length: 6
Display Cmd (switch): Cursor Control (0x10)
1000 0001 = FLAGS: For Following Byte
.... 0001 = Cursor Movement Command: Set cursor at the
address specified in the following byte (0x01)
1... .... = Should Cursor Blink: True
0000 0100 = FLAGS: For Following Byte
.... ...0 = Is Address Numberic: False
.... ..0. = Context Field in the Info Bar: False
.... .1.. = Write A Line: True
.... 0... = Write a SoftKey: False
0000 0000 = FLAGS: For Following Byte
...0 0000 = Character Position or Soft-Label Key ID: 0x00
000. .... = Line Number: 0
Thanx,
John