Wireshark-commits: [Wireshark-commits] rev 45793: /trunk/epan/dissectors/ /trunk/epan/dissectors/:
Date: Fri, 26 Oct 2012 02:15:20 GMT
http://anonsvn.wireshark.org/viewvc/viewvc.cgi?view=rev&revision=45793

User: mmann
Date: 2012/10/25 07:15 PM

Log:
 Improve Modbus/TCP dissector, Part 1
 
 This is a portion of the patch supplied in bug 7902 (https://bugs.wireshark.org/bugzilla/show_bug.cgi?id=7902).  Breaking the functionality up into smaller chunks.
 
 This definitively breaks the Modbus dissection into 3 dissectors:
 Modbus - real protocol PDU
 Modbus/TCP - Encapsulation of Modbus over TCP (with a small header before PDU)
 Modbus RTU - Originally an encapsulation of Modbus over serial (with smaller header + CRC), but can also be sent over TCP.
 
 General cleanup/refactoring (including display filter names) based on the 3 dissectors.
 Also included:
 1. Enhanced dissection to include preferences for register data to be dissected as UINT16, UINT32 or FLOAT
 2. Dynamic port registration
 3. Additional fields now filterable

Directory: /trunk/epan/dissectors/
  Changes    Path              Action
  +11 -2     packet-cip.c      Modified
  +779 -224  packet-mbtcp.c    Modified
  +40 -26    packet-mbtcp.h    Modified