Wireshark-bugs: [Wireshark-bugs] [Bug 9596] IEC60870-5-104 incorrect Integrated Totals parsing
Date: Sat, 04 Jan 2014 20:18:27 +0000

Comment # 6 on bug 9596 from
Hi again,

The pride of being able to report here has led me to investigate around a bit.
Found this:

911     /* ====================================================================
912     todo -- BCR: Binary counter reading
913     ==================================================================== */
914     /* void get_BCR(guint8 *offset, proto_tree *iec104_header_tree); */
915     
916     /* ====================================================================
917     todo -- SEP: Single event of protection equipment
918     ==================================================================== */
919     #if 0
920     static void get_SEP(tvbuff_t *tvb _U_, guint8 *offset _U_, proto_tree
*iec104_header_tree _U_)
921     {
922     /* todo */
923     
924     }
925     #endif

I believe Binary Counters are in fact Integrated totals. The SEP probably also
needs some work, although I do not use it in my application.

Cheers,
Jaka


You are receiving this mail because:
  • You are watching all bug changes.