This code
case 162: /* flowDurationMicroseconds */
msec_delta = tvb_get_ntohl(tvb, offset);
ts_delta.secs = msec_delta / 1000000;
ts_delta.nsecs = (msec_delta % 1000000) * 1000000;
ti = proto_tree_add_time(pdutree, hf_cflow_timedelta, tvb,
offset, length, &ts_delta);
break;
seems to wrong. The ts_delta.nsecs assignment should be:
ts_delta.nsecs = (msec_delta % 1000000) * 1000;
Note that msec_delta is in microseconds and hence multiplying by 1000 gives you
nanoseconds. I assume this is a cut'n'paste bug from flowDura.tionMilliseconds