I have put this post on both the users & the
dev lists, as I am not sure which is the best one.
I have been doing some testing with the latest
pre-release of 0.10.7 (ethereal-setup-20040930161108.exe) on Win98SE, Win2k
& WinXP. This is what I have encountered:-
All Versions:-
The Capture Filter Dialog has the "OK" button
missing on it.
Win98SE:-
With WinPcap 3.1 beta 3 the program stops
responding when trying to open the main capture dialog and also the preferences
one. However, both work OK with WinPcap 3.0 final. As far as I can see there are
no other problems under Win98SE.
Win2K:-
Using WinPcap 3.1 beta 3 I could find no
problems.
Win XP Pro (SP2):-
With Winpcap 3.1 beta 3 no problems on capture, but
when trying to save you get a DOS box with the following errors:-
Gdk-Warning
gdkdrawable-win32.c:1587: BitBlt failed: The handle
is invalid
adns warning:
datagram receive error :Unknown error
I have seen a
post that suggests a problem with name resolution for this latter one, but I am
only using the default of MAC & Transport name resolution. However I have
noticed a new option under name resolution in the preferences of "Enable
concurrent DNS name resolution" which was ticked. Unticking this seems to have
sorted these problems and it now saves OK.
Keith
French.
--- Outgoing mail is certified Virus Free. Checked by AVG
anti-virus system (http://www.grisoft.com). Version: 6.0.772 /
Virus Database: 519 - Release Date: 01/10/2004
|