Hi Thomas,
> PS: I hope it's the right place for bug reports, i've not found any info
> on where to submit them on ethereal.zing.org.
I guess, it is...
The crash happens because of the fixed size vb_display_string variable in
snmp_variable_decode(). This is what gdb shows:
Program received signal SIGSEGV, Segmentation fault.
0x401e9000 in g_node_insert_before () from /usr/lib/libglib-1.2.so.0
(gdb) where
#0 0x401e9000 in g_node_insert_before () from /usr/lib/libglib-1.2.so.0
#1 0x80e14ec in proto_tree_add_node (tree=0x2e313130, fi=0x8242668)
at proto.c:1312
#2 0x80e15d9 in proto_tree_add_pi (tree=0x2e313130, hfindex=1549,
tvb=0x0,
start=774975537, length=503, pfi=0x0) at proto.c:1344
#3 0x80e01d2 in proto_tree_add_notext (tree=0x2e313130, tvb=0x0,
start=774975537, length=503) at proto.c:277
#4 0x80e01f4 in proto_tree_add_text (tree=0x2e313130, tvb=0x0,
start=774975537, length=503, format=0x815a855 "Value: %s: %s")
at proto.c:292
#5 0x80bd92a in snmp_variable_decode (snmp_tree=0x2e313130,
variable_oid=0x2e323030, variable_oid_length=775237680,
asn1=0x2e303530,
offset=774975537, lengthp=0x2e393031) at packet-snmp.c:789
#6 0x2e313030 in ?? ()
Cannot access memory at address 0x2e313030
Clearly, the tree variable and the stack return address are trashed. The
libsmi version doesn't have this problem (although somehow the decoded
OBJECT STRING looks truncated). The length of the OBJECT STRING in the
captured packet is 499, so to print this in binary, at least 1497 bytes
would be needed instead of the allocated 1024...
I've attached the 3 MIB files needed to get a propper object ID decoding.
The CVS version shows a second problem in this trace: the request packets
are decoded with a wrong protocol type due to the source port having
precedence over the destination port. There should be a way to override
the automatic protocol detection if necessary.
Cheers,
Jochen
A3Com-products-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises FROM RFC1155-SMI;
--
-- This MIB contains 3com product OIDs (used in sysObjectID)
--
a3Com OBJECT IDENTIFIER ::= { enterprises 43 }
products OBJECT IDENTIFIER ::= { a3Com 1 }
brouterMIB OBJECT IDENTIFIER ::= { a3Com 2 }
amp-mib OBJECT IDENTIFIER ::= { a3Com 3 }
genericTrap OBJECT IDENTIFIER ::= { a3Com 4 }
viewBuilderApps OBJECT IDENTIFIER ::= { a3Com 5 }
specificTrap OBJECT IDENTIFIER ::= { a3Com 6 }
linkBuilder3GH-mib OBJECT IDENTIFIER ::= { a3Com 7 }
linkBuilder10BTi-mib OBJECT IDENTIFIER ::= { a3Com 8 }
linkBuilderECS-mib OBJECT IDENTIFIER ::= { a3Com 9 }
generic OBJECT IDENTIFIER ::= { a3Com 10 }
netBuilder-mib OBJECT IDENTIFIER ::= { a3Com 11 }
lBridgeECS-mib OBJECT IDENTIFIER ::= { a3Com 12 }
deskMan OBJECT IDENTIFIER ::= { a3Com 13 }
linkBuilderMSH-mib OBJECT IDENTIFIER ::= { a3Com 14 }
a3ComUnused15 OBJECT IDENTIFIER ::= { a3Com 15 }
a3comFddiWGHubMib OBJECT IDENTIFIER ::= { a3Com 16 }
linkSwitch OBJECT IDENTIFIER ::= { a3Com 17 }
linkSwitch1000-mib OBJECT IDENTIFIER ::= { a3Com 18 }
linkBuilderFMS100-mib OBJECT IDENTIFIER ::= { a3Com 19 }
ncdMibs OBJECT IDENTIFIER ::= { a3Com 20 }
officeConnect-Hub8M-mib OBJECT IDENTIFIER ::= { a3Com 21 }
linkSwitch2000TR-mib OBJECT IDENTIFIER ::= { a3Com 22 }
vlanServer-mib OBJECT IDENTIFIER ::= { a3Com 23 }
terminalServerMib OBJECT IDENTIFIER ::= { a3Com 24 }
terminalServer OBJECT IDENTIFIER ::= { products 1 }
dedicatedBridgeServer OBJECT IDENTIFIER ::= { products 2 }
dedicatedRouteServer OBJECT IDENTIFIER ::= { products 3 }
brouter OBJECT IDENTIFIER ::= { products 4 }
genericMSWorkstation OBJECT IDENTIFIER ::= { products 5 }
genericMSServer OBJECT IDENTIFIER ::= { products 6 }
genericUnixServer OBJECT IDENTIFIER ::= { products 7 }
hub OBJECT IDENTIFIER ::= { products 8 }
cards OBJECT IDENTIFIER ::= { products 9 }
chipSets OBJECT IDENTIFIER ::= { products 10 }
oem OBJECT IDENTIFIER ::= { products 11 }
atm OBJECT IDENTIFIER ::= { products 12 }
--
-- the following identifiers are assigned to 3com terminal servers
--
cs2500 OBJECT IDENTIFIER ::= { terminalServer 1 }
cs2600 OBJECT IDENTIFIER ::= { terminalServer 2 }
cs2000 OBJECT IDENTIFIER ::= { terminalServer 3 }
cs1 OBJECT IDENTIFIER ::= { terminalServer 4 }
cs210 OBJECT IDENTIFIER ::= { terminalServer 5 }
cs2100 OBJECT IDENTIFIER ::= { terminalServer 6 }
cs3000 OBJECT IDENTIFIER ::= { terminalServer 7 }
cs3100 OBJECT IDENTIFIER ::= { terminalServer 8 }
callisto OBJECT IDENTIFIER ::= { terminalServer 9 }
termServerPlatform OBJECT IDENTIFIER ::= { terminalServer 10 }
--
-- the following ids are assigned under a3Com.products.terminalServer.cs2500
--
cs2500to OBJECT IDENTIFIER ::= { cs2500 1 }
cs2500tlo OBJECT IDENTIFIER ::= { cs2500 2 }
--
-- the following ids are assigned under a3Com.products.terminalServer.cs2600
--
cs2600to OBJECT IDENTIFIER ::= { cs2600 1 }
cs2600tlo OBJECT IDENTIFIER ::= { cs2600 2 }
--
-- the following ids are assigned under a3Com.products.terminalServer.cs2000
--
cs2000to OBJECT IDENTIFIER ::= { cs2000 1 }
cs2000tlo OBJECT IDENTIFIER ::= { cs2000 2 }
--
-- the following ids are assigned under a3Com.products.terminalServer.cs2100
--
cs2100to OBJECT IDENTIFIER ::= { cs2100 1 }
cs2100tlo OBJECT IDENTIFIER ::= { cs2100 2 }
--
-- the following ids are assigned under a3Com.products.terminalServer.cs3000
--
cs3000to OBJECT IDENTIFIER ::= { cs3000 1 }
cs3000tlo OBJECT IDENTIFIER ::= { cs3000 2 }
--
-- the following ids are assigned under a3Com.products.terminalServer.cs3100
--
cs3100to OBJECT IDENTIFIER ::= { cs3100 1 }
cs3100tlo OBJECT IDENTIFIER ::= { cs3100 2 }
--
-- the following identifiers are assigned to 3com terminal server platforms
--
series1 OBJECT IDENTIFIER ::= { termServerPlatform 1 }
series200 OBJECT IDENTIFIER ::= { termServerPlatform 2 }
callistoPlatfor OBJECT IDENTIFIER ::= { termServerPlatform 3 }
series2500 OBJECT IDENTIFIER ::= { termServerPlatform 4 }
series3000 OBJECT IDENTIFIER ::= { termServerPlatform 5 }
--
-- the following identifiers are assigned to 3com brouters
--
netbuilder1 OBJECT IDENTIFIER ::= { brouter 1 } -- not used
netbuilder2 OBJECT IDENTIFIER ::= { brouter 2 } -- >= 6.2
lBridgeECS OBJECT IDENTIFIER ::= { brouter 3 }
netbuilderTrRA OBJECT IDENTIFIER ::= { brouter 4 } -- 2 port nbtr NBTR Remote Access
brouterPlatform OBJECT IDENTIFIER ::= { brouter 5 }
netbuilderRem OBJECT IDENTIFIER ::= { brouter 6 } -- 4 port nb1 NB Remote
netbuilderRA OBJECT IDENTIFIER ::= { brouter 7 } -- 2 port nb1 NB Remote Access
netbuilderRC OBJECT IDENTIFIER ::= { brouter 8 } -- 2 port boundary rtr NB Remote Control
netbuilderTrRem OBJECT IDENTIFIER ::= { brouter 9 } -- 4 port tok.ring nb1 NBTR Remote
netbuilderTrRC OBJECT IDENTIFIER ::= { brouter 10 } -- tok.ring boundary rtr NBTR Remote Control
nb2-4 OBJECT IDENTIFIER ::= { brouter 11 } -- 4 port nb2
nb2-8 OBJECT IDENTIFIER ::= { brouter 12 } -- 8 port nb2
nbro OBJECT IDENTIFIER ::= { brouter 13 } -- netbuilder Rem. Office (spectre)
brouterBoards OBJECT IDENTIFIER ::= { brouter 14 }
netbuilderLocal OBJECT IDENTIFIER ::= { brouter 15 } -- 2 Lan nb1 NB Local
netbuilderTrLocal OBJECT IDENTIFIER ::= { brouter 16 } -- 2 Lan nbtr NBTR Local
netbuilderRC1x2 OBJECT IDENTIFIER ::= { brouter 17 } -- NB Rem Ctl w/2 wan ports
netbuilderTrRC1x2 OBJECT IDENTIFIER ::= { brouter 18 } -- NBTR Rem Ctl w/2 wan ports
casper OBJECT IDENTIFIER ::= { brouter 19 } -- Spectre Large
spectreHuge OBJECT IDENTIFIER ::= { brouter 20 } -- Spectre Huge
spectreIsdn OBJECT IDENTIFIER ::= { brouter 21 } -- Spectre ISDN
nb2-8-4fddi OBJECT IDENTIFIER ::= { brouter 22 } -- 8 port nb2 capable of 4 fddi sets
nb2-8-dualwide OBJECT IDENTIFIER ::= { brouter 23 } -- 8 port nb2 w/dual wide slots 4 crew
brouterBrdFwVers OBJECT IDENTIFIER ::= { brouter 24 } -- fw versions
brouterBrdSwVers OBJECT IDENTIFIER ::= { brouter 25 } -- sw versions
spectreIsdnHuge OBJECT IDENTIFIER ::= { brouter 26 } -- Spectre ISDN
nbroTrLarge OBJECT IDENTIFIER ::= { brouter 27 }--SpectreTR4x8
nbroTrIsdn OBJECT IDENTIFIER ::= { brouter 28 } -- SpectreTrIsdn4x8
nbroTrHuge OBJECT IDENTIFIER ::= { brouter 29 }--SpectreTrxxx
nbro2Eth OBJECT IDENTIFIER ::= { brouter 30 } -- Spectre2Eth
nbro2EthIsdn OBJECT IDENTIFIER ::= { brouter 31 } -- Spectre2EthIsdn
officeConnRtr OBJECT IDENTIFIER ::= { brouter 32 } -- officeConnect
--
-- the following ids are assigned under a3Com.products.brouter.netbuilderTrRA
--
netbuilderTrRAbp OBJECT IDENTIFIER ::= { netbuilderTrRA 1 } -- NBTR Rem. Acc. w/Basic Prot. SW
netbuilderTrRAcp OBJECT IDENTIFIER ::= { netbuilderTrRA 2 } -- NBTR Rem. Acc. w/Compl. Prot. SW
netbuilderTrRAxw OBJECT IDENTIFIER ::= { netbuilderTrRA 3 } -- NBTR Rem. Acc w/Ext. WAN SW
netbuilderTrRAcx OBJECT IDENTIFIER ::= { netbuilderTrRA 4 } -- NBTR Rem. Acc. w/Con Svc SW
netbuilderTrRAba OBJECT IDENTIFIER ::= { netbuilderTrRA 5 } -- NBTR Rem. Acc. w/Bndry Rtg Clnt
netbuilderTrRAar OBJECT IDENTIFIER ::= { netbuilderTrRA 6 } -- NBTR Rem. Acc. w/Acc. Rtr SW
netbuilderTrRAsn OBJECT IDENTIFIER ::= { netbuilderTrRA 7 } -- NBTR Rem. Acc. w/SNA SW
netbuilderTrRArb OBJECT IDENTIFIER ::= { netbuilderTrRA 8 } -- NBTR RA w/RB SW
netbuilderTrRAff OBJECT IDENTIFIER ::= { netbuilderTrRA 9 } -- NBTR RA w/Full Feature SW
netbuidlerTrRAcf OBJECT IDENTIFIER ::= { netbuilderTrRA 10 } -- NBTR RA w/CF SW
netbuilderTrRAbx OBJECT IDENTIFIER ::= { netbuilderTrRA 11 } -- NBTR Rem Acc w/BX SW
netbuilderTrRAappn OBJECT IDENTIFIER ::= { netbuilderTrRA 12 } -- NBTR RAAcc w/Appn SW
netbuilderTrRAlm OBJECT IDENTIFIER ::= { netbuilderTrRA 13 } -- NBTR RA w/L Sw
netbuilderTrRAlt OBJECT IDENTIFIER ::= { netbuilderTrRA 14 } -- NBTR RA w/Lt Sw
netbuilderTrRAwm OBJECT IDENTIFIER ::= { netbuilderTrRA 15 } -- NBTR RA w/Wm Sw
netbuilderTrRAwt OBJECT IDENTIFIER ::= { netbuilderTrRA 16 } -- NBTR RA w/Wt Sw
netbuilderTrRAae OBJECT IDENTIFIER ::= { netbuilderTrRA 17 } -- NBTR RA w/Ae Sw
netbuilderTrRAap OBJECT IDENTIFIER ::= { netbuilderTrRA 18 } -- NBTR RA w/Ap Sw
netbuilderTrRAan OBJECT IDENTIFIER ::= { netbuilderTrRA 19 } -- NBTR RA w/An Sw
netbuilderTrRAla OBJECT IDENTIFIER ::= { netbuilderTrRA 20 } -- NBTR RA w/La Sw
netbuilderTrRAwa OBJECT IDENTIFIER ::= { netbuilderTrRA 21 } -- NBTR RA w/Wa Sw
netbuilderTrRAaa OBJECT IDENTIFIER ::= { netbuilderTrRA 22 } -- NBTR RA w/Aa Sw
netbuilderTrRAab OBJECT IDENTIFIER ::= { netbuilderTrRA 23 } -- NBTR RA w/Ab Sw
netbuilderTrRAbf OBJECT IDENTIFIER ::= { netbuilderTrRA 24 } -- NBTR RA w/Bf Sw
--
-- the following identifiers are assigned to brouterPlatform
--
nb1 OBJECT IDENTIFIER ::= { brouterPlatform 1 } -- nb1 platform
nb2 OBJECT IDENTIFIER ::= { brouterPlatform 2 } -- nb2 platform
nbroPlatform OBJECT IDENTIFIER ::= { brouterPlatform 3 } -- netbuilder remote office platform
casperPlatform OBJECT IDENTIFIER ::= { brouterPlatform 4 } -- Casper platform
spectreIsdnPform OBJECT IDENTIFIER ::= { brouterPlatform 5 } -- spec.isdn pf
spectreIITr OBJECT IDENTIFIER ::= { brouterPlatform 6 }--spec.IITr pf
--
-- the following id are assigned under a3Com.products.brouter.netbuilderRem
--
netbuilderRemBp OBJECT IDENTIFIER ::= { netbuilderRem 1 } -- nb Rem. w/Basic Prot
netbuilderRemCp OBJECT IDENTIFIER ::= { netbuilderRem 2 } -- nb Rem w/Compl Prot
netbuilderRemXw OBJECT IDENTIFIER ::= { netbuilderRem 3 } -- nb Rem w/Ext WAN
netbuilderRemCx OBJECT IDENTIFIER ::= { netbuilderRem 4 } -- nb Rem w/X25 Con Svc
netbuilderRemBa OBJECT IDENTIFIER ::= { netbuilderRem 5 } -- nb Rem w/Bndry Rtg
netbuilderRemAr OBJECT IDENTIFIER ::= { netbuilderRem 6 } -- nb Rem w/Acc Rtr SW
netbuilderRemSn OBJECT IDENTIFIER ::= { netbuilderRem 7 } -- nb Rem w/SNA SW
netbuilderRemRb OBJECT IDENTIFIER ::= { netbuilderRem 8 } -- nb Rem w/RB SW
netbuilderRemFf OBJECT IDENTIFIER ::= { netbuilderRem 9 } -- nb Remw/FF SW
netbuilderRemCf OBJECT IDENTIFIER ::= { netbuilderRem 10 } -- nb Rem w/CF SW
netbuilderRemBx OBJECT IDENTIFIER ::= { netbuilderRem 11 } -- nb Rem w/BX SW
netbuilderRemAppn OBJECT IDENTIFIER ::= { netbuilderRem 12 } -- nb Rem w/Appn SW
netbuilderRemLm OBJECT IDENTIFIER ::= { netbuilderRem 13 } -- nb Rem w/Lm Sw
netbuilderRemLt OBJECT IDENTIFIER ::= { netbuilderRem 14 } -- nb Rem w/Lt Sw
netbuilderRemWm OBJECT IDENTIFIER ::= { netbuilderRem 15 } -- nb Rem w/Wm Sw
netbuilderRemWt OBJECT IDENTIFIER ::= { netbuilderRem 16 } -- nb Rem w/Wt Sw
netbuilderRemAe OBJECT IDENTIFIER ::= { netbuilderRem 17 } -- nb Rem w/Ae Sw
netbuilderRemAp OBJECT IDENTIFIER ::= { netbuilderRem 18 } -- nb Rem w/Ap Sw
netbuilderRemAn OBJECT IDENTIFIER ::= { netbuilderRem 19 } -- nb Rem w/An Sw
netbuilderRemLa OBJECT IDENTIFIER ::= { netbuilderRem 20 } -- nb Rem w/La Sw
netbuilderRemWa OBJECT IDENTIFIER ::= { netbuilderRem 21 } -- nb Rem w/Wa Sw
netbuilderRemAa OBJECT IDENTIFIER ::= { netbuilderRem 22 } -- nb Rem w/Aa Sw
netbuilderRemAb OBJECT IDENTIFIER ::= { netbuilderRem 23 } -- nb Rem w/Ab Sw
netbuilderRemBf OBJECT IDENTIFIER ::= { netbuilderRem 24 } -- nb Rem w/Bf Sw
--
-- the following ids are assigned under a3Com.products.brouter.netbuilderRA
--
netbuilderRAbp OBJECT IDENTIFIER ::= { netbuilderRA 1 } -- nb RA w/Basic Prot
netbuilderRAcp OBJECT IDENTIFIER ::= { netbuilderRA 2 } -- nb RA w/Compl Prot
netbuilderRAxw OBJECT IDENTIFIER ::= { netbuilderRA 3 } -- nb RA w/Ext WAN
netbuilderRAcx OBJECT IDENTIFIER ::= { netbuilderRA 4 } -- nb RA w/Conn Svc
netbuilderRAba OBJECT IDENTIFIER ::= { netbuilderRA 5 } -- nb RA w/Bndry Rtg
netbuilderRAar OBJECT IDENTIFIER ::= { netbuilderRA 6 } -- nb RA w/AccRtr SW
netbuilderRAsn OBJECT IDENTIFIER ::= { netbuilderRA 7 } -- nb RA w/SNA SW
netbuilderRArb OBJECT IDENTIFIER ::= { netbuilderRA 8 } -- nb RA w/RB SW
netbuilderRAff OBJECT IDENTIFIER ::= { netbuilderRA 9 } -- nb RA/FF SW
netbuilderRAcf OBJECT IDENTIFIER ::= { netbuilderRA 10 } -- nb RA w/CF SW
netbuilderRAbx OBJECT IDENTIFIER ::= { netbuilderRA 11 } -- nb RA w/BX SW
netbuilderRAappn OBJECT IDENTIFIER ::= { netbuilderRA 12 } -- nb RA w/Appn SW
netbuilderRAlm OBJECT IDENTIFIER ::= { netbuilderRA 13 } -- nb RA w/Lm Sw
netbuilderRAlt OBJECT IDENTIFIER ::= { netbuilderRA 14 } -- nb RA w/Lt Sw
netbuilderRAwm OBJECT IDENTIFIER ::= { netbuilderRA 15 } -- nb RA w/Wm Sw
netbuilderRAwt OBJECT IDENTIFIER ::= { netbuilderRA 16 } -- nb RA w/Wt Sw
netbuilderRAae OBJECT IDENTIFIER ::= { netbuilderRA 17 } -- nb RA w/Ae Sw
netbuilderRAap OBJECT IDENTIFIER ::= { netbuilderRA 18 } -- nb RA w/Ap Sw
netbuilderRAan OBJECT IDENTIFIER ::= { netbuilderRA 19 } -- nb RA w/An Sw
netbuilderRAla OBJECT IDENTIFIER ::= { netbuilderRA 20 } -- nb RA w/La Sw
netbuilderRAwa OBJECT IDENTIFIER ::= { netbuilderRA 21 } -- nb RA w/Wa Sw
netbuilderRAaa OBJECT IDENTIFIER ::= { netbuilderRA 22 } -- nb RA w/Aa Sw
netbuilderRAab OBJECT IDENTIFIER ::= { netbuilderRA 23 } -- nb RA w/Ab Sw
netbuilderRAbf OBJECT IDENTIFIER ::= { netbuilderRA 24 } -- nb RA w/Bf Sw
--
-- the following ids are assigned under a3Com.products.brouter.netbuilderRC
--
netbuilderRCbp OBJECT IDENTIFIER ::= { netbuilderRC 1 } -- nb RC w/Basic Prot
netbuilderRCcp OBJECT IDENTIFIER ::= { netbuilderRC 2 } -- nb RC w/Compl Prot
netbuilderRCxw OBJECT IDENTIFIER ::= { netbuilderRC 3 } -- nb RC w/Ext WAN
netbuilderRCcx OBJECT IDENTIFIER ::= { netbuilderRC 4 } -- nb RC w/Conn Svc
netbuilderRCba OBJECT IDENTIFIER ::= { netbuilderRC 5 } -- nb RC w/Bndry Rtg
netbuilderRCar OBJECT IDENTIFIER ::= { netbuilderRC 6 } -- nb RC w/AccRtr SW
netbuilderRCsn OBJECT IDENTIFIER ::= { netbuilderRC 7 } -- nb RC w/SNA SW
netbuilderRCrb OBJECT IDENTIFIER ::= { netbuilderRC 8 } -- nb RC w/RB SW
netbuilderRCff OBJECT IDENTIFIER ::= { netbuilderRC 9 } -- nb RC w/FF SW
netbuilderRCcf OBJECT IDENTIFIER ::= { netbuilderRC 10 } -- nb RC w/CF SW
netbuilderRCbx OBJECT IDENTIFIER ::= { netbuilderRC 11 } -- nb RC w/BX SW
netbuilderRCappn OBJECT IDENTIFIER ::= { netbuilderRC 12 } -- nb RC w/Appn SW
netbuilderRClm OBJECT IDENTIFIER ::= { netbuilderRC 13 } -- nb RC w/Lm Sw
netbuilderRClt OBJECT IDENTIFIER ::= { netbuilderRC 14 } -- nb RC w/Lt Sw
netbuilderRCwm OBJECT IDENTIFIER ::= { netbuilderRC 15 } -- nb RC w/Wm Sw
netbuilderRCwt OBJECT IDENTIFIER ::= { netbuilderRC 16 } -- nb RC w/Wt Sw
netbuilderRCae OBJECT IDENTIFIER ::= { netbuilderRC 17 } -- nb RC w/Ae Sw
netbuilderRCap OBJECT IDENTIFIER ::= { netbuilderRC 18 } -- nb RC w/Ap Sw
netbuilderRCan OBJECT IDENTIFIER ::= { netbuilderRC 19 } -- nb RC w/An Sw
netbuilderRCla OBJECT IDENTIFIER ::= { netbuilderRC 20 } -- nb RC w/La Sw
netbuilderRCwa OBJECT IDENTIFIER ::= { netbuilderRC 21 } -- nb RC w/Wa Sw
netbuilderRCaa OBJECT IDENTIFIER ::= { netbuilderRC 22 } -- nb RC w/Aa Sw
netbuilderRCab OBJECT IDENTIFIER ::= { netbuilderRC 23 } -- nb RC w/Ab Sw
netbuilderRCbf OBJECT IDENTIFIER ::= { netbuilderRC 24 } -- nb RC w/Bf Sw
--
-- the following ids are assigned under a3Com.products.brouter.netbuilderTrRem
--
netbuilderTrRemBp OBJECT IDENTIFIER ::= { netbuilderTrRem 1 } -- nbtr Rem w/BP
netbuilderTrRemCp OBJECT IDENTIFIER ::= { netbuilderTrRem 2 } -- nbtr Rem w/CP
netbuilderTrRemXw OBJECT IDENTIFIER ::= { netbuilderTrRem 3 } -- nbtr Rem w/XW
netbuilderTrRemCx OBJECT IDENTIFIER ::= { netbuilderTrRem 4 } -- nbtr Rem w/CX
netbuilderTrRemBa OBJECT IDENTIFIER ::= { netbuilderTrRem 5 } -- nbtr Rem w/BA
netbuilderTrRemAr OBJECT IDENTIFIER ::= { netbuilderTrRem 6 } -- nbtr Rem w/AR
netbuilderTrRemSn OBJECT IDENTIFIER ::= { netbuilderTrRem 7 } -- nbtr Rem w/SNA
netbuilderTrRemRb OBJECT IDENTIFIER ::= { netbuilderTrRem 8 } -- nb TrRem w/RB
netbuilderTrRemFf OBJECT IDENTIFIER ::= { netbuilderTrRem 9 } -- nb TrRem w/FF
netbuilderTrRemCf OBJECT IDENTIFIER ::= { netbuilderTrRem 10 } -- nb TrRem w/CF
netbuilderTrRemBx OBJECT IDENTIFIER ::= { netbuilderTrRem 11 } -- nbtr Rem w/BX
netbuilderTrRemAppn OBJECT IDENTIFIER ::= { netbuilderTrRem 12 } -- nb TrRem w/Appn SW
netbuilderTrRemLm OBJECT IDENTIFIER ::= { netbuilderTrRem 13 } -- nb TrRem w/Lm
netbuilderTrRemLt OBJECT IDENTIFIER ::= { netbuilderTrRem 14 } -- nb TrRem w/Lt
netbuilderTrRemWm OBJECT IDENTIFIER ::= { netbuilderTrRem 15 } -- nb TrRem w/Wm
netbuilderTrRemWt OBJECT IDENTIFIER ::= { netbuilderTrRem 16 } -- nb TrRem w/Wt
netbuilderTrRemAe OBJECT IDENTIFIER ::= { netbuilderTrRem 17 } -- nb TrRem w/Ae
netbuilderTrRemAp OBJECT IDENTIFIER ::= { netbuilderTrRem 18 } -- nb TrRem w/Ap
netbuilderTrRemAn OBJECT IDENTIFIER ::= { netbuilderTrRem 19 } -- nb TrRem w/An
netbuilderTrRemLa OBJECT IDENTIFIER ::= { netbuilderTrRem 20 } -- nb TrRem w/La
netbuilderTrRemWa OBJECT IDENTIFIER ::= { netbuilderTrRem 21 } -- nb TrRem w/La
netbuilderTrRemAa OBJECT IDENTIFIER ::= { netbuilderTrRem 22 } -- nb TrRem w/Aa
netbuilderTrRemAb OBJECT IDENTIFIER ::= { netbuilderTrRem 23 } -- nb TrRem w/Ab
netbuilderTrRemBf OBJECT IDENTIFIER ::= { netbuilderTrRem 24 } -- nb TrRem w/Bf
--
-- the following ids are assigned under a3Com.products.brouter.netbuilderTrRC
--
netbuilderTrRCbp OBJECT IDENTIFIER ::= { netbuilderTrRC 1 } -- NBTR RC w/Basic Prot
netbuilderTrRCcp OBJECT IDENTIFIER ::= { netbuilderTrRC 2 } -- NBTR Rc w/Compl Prot
netbuilderTrRCxw OBJECT IDENTIFIER ::= { netbuilderTrRC 3 } -- NBTR Rc w/Ext WAN
netbuilderTrRCcx OBJECT IDENTIFIER ::= { netbuilderTrRC 4 } -- NBTR RC w/CX
netbuilderTrRCba OBJECT IDENTIFIER ::= { netbuilderTrRC 5 } -- NBTR RC w/BA
netbuilderTrRCar OBJECT IDENTIFIER ::= { netbuilderTrRC 6 } -- NBTR RC w/AR
netbuilderTrRCsn OBJECT IDENTIFIER ::= { netbuilderTrRC 7 } -- NBTR RC w/SNA
netbuilderTrRCrb OBJECT IDENTIFIER ::= { netbuilderTrRC 8 } -- NBTR RC w/RB
netbuilderTrRCff OBJECT IDENTIFIER ::= { netbuilderTrRC 9 } -- NBTR RC w/FF
netbuilderTrRCcf OBJECT IDENTIFIER ::= { netbuilderTrRC 10 } -- NBTR RC w/CF
netbuilderTrRCbx OBJECT IDENTIFIER ::= { netbuilderTrRC 11 } -- NBTR RC w/BX
netbuilderTrRCappn OBJECT IDENTIFIER ::= { netbuilderTrRC 12 } -- NBTR RC w/Appn SW
netbuilderTrRClm OBJECT IDENTIFIER ::= { netbuilderTrRC 13 } -- NBTR RC w/Lm
netbuilderTrRClt OBJECT IDENTIFIER ::= { netbuilderTrRC 14 } -- NBTR RC w/Lt
netbuilderTrRCwm OBJECT IDENTIFIER ::= { netbuilderTrRC 15 } -- NBTR RC w/Wm
netbuilderTrRCwt OBJECT IDENTIFIER ::= { netbuilderTrRC 16 } -- NBTR RC w/Wt
netbuilderTrRCae OBJECT IDENTIFIER ::= { netbuilderTrRC 17 } -- NBTR RC w/Ae
netbuilderTrRCap OBJECT IDENTIFIER ::= { netbuilderTrRC 18 } -- NBTR RC w/Ap
netbuilderTrRCan OBJECT IDENTIFIER ::= { netbuilderTrRC 19 } -- NBTR RC w/An
netbuilderTrRCla OBJECT IDENTIFIER ::= { netbuilderTrRC 20 } -- NBTR RC w/La
netbuilderTrRCwa OBJECT IDENTIFIER ::= { netbuilderTrRC 21 } -- NBTR RC w/Wa
netbuilderTrRCaa OBJECT IDENTIFIER ::= { netbuilderTrRC 22 } -- NBTR RC w/Aa
netbuilderTrRCab OBJECT IDENTIFIER ::= { netbuilderTrRC 23 } -- NBTR RC w/Ab
netbuilderTrRCbf OBJECT IDENTIFIER ::= { netbuilderTrRC 24 } -- NBTR RC w/Bf
--
-- the following identifiers are assigned under a3Com.products.brouter.nb2_4
--
nb2-4Bp OBJECT IDENTIFIER ::= { nb2-4 1 } -- nb2 4 slot w/Basic Prot SW
nb2-4Cp OBJECT IDENTIFIER ::= { nb2-4 2 } -- nb2 4 slot w/Compl Prot SW
nb2-4Xw OBJECT IDENTIFIER ::= { nb2-4 3 } -- nb2 4 slot w/Ext WAN SW
nb2-4Cx OBJECT IDENTIFIER ::= { nb2-4 4 } -- nb2 4 slot w/Conn Svc SW
nb2-4Ba OBJECT IDENTIFIER ::= { nb2-4 5 } -- nb2 4 slot w/BA
nb2-4Ar OBJECT IDENTIFIER ::= { nb2-4 6 } -- nb2 4 slot w/AR
nb2-4Sn OBJECT IDENTIFIER ::= { nb2-4 7 } -- nb2 4 slot w/SNA
nb2-4Rb OBJECT IDENTIFIER ::= { nb2-4 8 } -- nb2 4 slot w/RB
nb2-4Ff OBJECT IDENTIFIER ::= { nb2-4 9 } -- nb2 4 slot w/Full Feature SW
nb2-4Cf OBJECT IDENTIFIER ::= { nb2-4 10 } -- nb2 4 slot w/CF
nb2-4Bx OBJECT IDENTIFIER ::= { nb2-4 11 } -- nb2 4 slot w/BX
nb2-4Appn OBJECT IDENTIFIER ::= { nb2-4 12 } -- nb2 4 slot w/Appn SW
nb2-4Lm OBJECT IDENTIFIER ::= { nb2-4 13 } -- nb2 4 slot w/Lm Sw
nb2-4Lt OBJECT IDENTIFIER ::= { nb2-4 14 } -- nb2 4 slot w/Lt Sw
nb2-4Wm OBJECT IDENTIFIER ::= { nb2-4 15 } -- nb2 4 slot w/Wm Sw
nb2-4Wt OBJECT IDENTIFIER ::= { nb2-4 16 } -- nb2 4 slot w/Wt Sw
nb2-4Ae OBJECT IDENTIFIER ::= { nb2-4 17 } -- nb2 4 slot w/Ae Sw
nb2-4Ap OBJECT IDENTIFIER ::= { nb2-4 18 } -- nb2 4 slot w/Ap Sw
nb2-4An OBJECT IDENTIFIER ::= { nb2-4 19 } -- nb2 4 slot w/An Sw
nb2-4La OBJECT IDENTIFIER ::= { nb2-4 20 } -- nb2 4 slot w/La Sw
nb2-4Wa OBJECT IDENTIFIER ::= { nb2-4 21 } -- nb2 4 slot w/Wa Sw
nb2-4Aa OBJECT IDENTIFIER ::= { nb2-4 22 } -- nb2 4 slot w/Aa Sw
nb2-4Ab OBJECT IDENTIFIER ::= { nb2-4 23 } -- nb2 4 slot w/Ab Sw
nb2-4Bf OBJECT IDENTIFIER ::= { nb2-4 24 } -- nb2 4 slot w/Bf Sw
--
-- the following identifiers are assigned under a3Com.products.brouter.nb2_8
--
nb2-8Bp OBJECT IDENTIFIER ::= { nb2-8 1 } -- nb2 8 slot w/Basic Prot SW
nb2-8Cp OBJECT IDENTIFIER ::= { nb2-8 2 } -- nb2 8 slot w/Compl Prot SW
nb2-8Xw OBJECT IDENTIFIER ::= { nb2-8 3 } -- nb2 8 slot w/Ext WAN SW
nb2-8Cx OBJECT IDENTIFIER ::= { nb2-8 4 } -- nb2 8 slot w/Conn Svc SW
nb2-8Ba OBJECT IDENTIFIER ::= { nb2-8 5 } -- nb2 8 slot w/BA
nb2-8Ar OBJECT IDENTIFIER ::= { nb2-8 6 } -- nb2 8 slot w/AR
nb2-8Sn OBJECT IDENTIFIER ::= { nb2-8 7 } -- nb2 8 slot w/SNA
nb2-8Rb OBJECT IDENTIFIER ::= { nb2-8 8 } -- nb2 8 slot w/RB
nb2-8Ff OBJECT IDENTIFIER ::= { nb2-8 9 } -- nb2 8 slot w/Full Feature SW
nb2-8Cf OBJECT IDENTIFIER ::= { nb2-8 10 } -- nb2 8 slot w/CF
nb2-8Bx OBJECT IDENTIFIER ::= { nb2-8 11 } -- nb2 8 slot w/BX
nb2-8Appn OBJECT IDENTIFIER ::= { nb2-8 12 } -- nb2 8 slot w/Appn SW
nb2-8Lm OBJECT IDENTIFIER ::= { nb2-8 13 } -- nb2 8 slot w/Lm Sw
nb2-8Lt OBJECT IDENTIFIER ::= { nb2-8 14 } -- nb2 8 slot w/Lt Sw
nb2-8Wm OBJECT IDENTIFIER ::= { nb2-8 15 } -- nb2 8 slot w/Wm Sw
nb2-8Wt OBJECT IDENTIFIER ::= { nb2-8 16 } -- nb2 8 slot w/Wt Sw
nb2-8Ae OBJECT IDENTIFIER ::= { nb2-8 17 } -- nb2 8 slot w/Ae Sw
nb2-8Ap OBJECT IDENTIFIER ::= { nb2-8 18 } -- nb2 8 slot w/Ap Sw
nb2-8An OBJECT IDENTIFIER ::= { nb2-8 19 } -- nb2 8 slot w/An Sw
nb2-8La OBJECT IDENTIFIER ::= { nb2-8 20 } -- nb2 8 slot w/La Sw
nb2-8Wa OBJECT IDENTIFIER ::= { nb2-8 21 } -- nb2 8 slot w/Wa Sw
nb2-8Aa OBJECT IDENTIFIER ::= { nb2-8 22 } -- nb2 8 slot w/Aa Sw
nb2-8Ab OBJECT IDENTIFIER ::= { nb2-8 23 } -- nb2 8 slot w/Ab Sw
nb2-8Bf OBJECT IDENTIFIER ::= { nb2-8 24 } -- nb2 8 slot w/Bf Sw
--
-- the following identifiers are assigned under a3Com.products.brouter.nbro
--
nbroBp OBJECT IDENTIFIER ::= { nbro 1 } -- nbro w/Basic Prot SW
nbroCp OBJECT IDENTIFIER ::= { nbro 2 } -- nbro w/Compl Prot SW
nbroXw OBJECT IDENTIFIER ::= { nbro 3 } -- nbro w/Ext WAN SW
nbroCx OBJECT IDENTIFIER ::= { nbro 4 } -- nbro w/Conn Svc SW
nbro201 OBJECT IDENTIFIER ::= { nbro 5 } -- nbro w/Bndry Rtg. SW
nbroAr OBJECT IDENTIFIER ::= { nbro 6 } -- nbro w/AR
nbroSn OBJECT IDENTIFIER ::= { nbro 7 } -- nbro w/SNA
nbro200 OBJECT IDENTIFIER ::= { nbro 8 } -- nbro w/Bridge Prd. SW
nbroFf OBJECT IDENTIFIER ::= { nbro 9 } -- nbro w/Full Feature SW
nbroCf OBJECT IDENTIFIER ::= { nbro 10 } -- nbro w/CF
nbroBx OBJECT IDENTIFIER ::= { nbro 11 } -- nbro w/BX
nbroAppn OBJECT IDENTIFIER ::= { nbro 12 } -- nbro w/Appn SW
nbroLm OBJECT IDENTIFIER ::= { nbro 13 } -- nbro w/Lm Sw
nbroLt OBJECT IDENTIFIER ::= { nbro 14 } -- nbro w/Lt Sw
nbroWm OBJECT IDENTIFIER ::= { nbro 15 } -- nbro w/Wm Sw
nbroWt OBJECT IDENTIFIER ::= { nbro 16 } -- nbro w/Wt Sw
nbroAe OBJECT IDENTIFIER ::= { nbro 17 } -- nbro w/Ae Sw
nbroAp OBJECT IDENTIFIER ::= { nbro 18 } -- nbro w/Ap Sw
nbroAn OBJECT IDENTIFIER ::= { nbro 19 } -- nbro w/An Sw
nbroLa OBJECT IDENTIFIER ::= { nbro 20 } -- nbro w/La Sw
nbroWa OBJECT IDENTIFIER ::= { nbro 21 } -- nbro w/Wa Sw
nbro224 OBJECT IDENTIFIER ::= { nbro 22 } -- nbro w/Aa Sw
nbroAb OBJECT IDENTIFIER ::= { nbro 23 } -- nbro w/Ab Sw
nbro223 OBJECT IDENTIFIER ::= { nbro 24 } -- nbro w/Bf Sw
--
-- the following identifier are assigned under a3Com.products.brouter.netbuilderLocal
--
netbuilderLocalBp OBJECT IDENTIFIER ::= { netbuilderLocal 1 } -- nb Local w/BP
netbuilderLocalCp OBJECT IDENTIFIER ::= { netbuilderLocal 2 } -- nb Local w/CP
netbuilderLocalXw OBJECT IDENTIFIER ::= { netbuilderLocal 3 } -- nb Local w/XW
netbuilderLocalCx OBJECT IDENTIFIER ::= { netbuilderLocal 4 } -- nb Local w/CX
netbuilderLocalBa OBJECT IDENTIFIER ::= { netbuilderLocal 5 } -- nb Local w/BA
netbuilderLocalAr OBJECT IDENTIFIER ::= { netbuilderLocal 6 } -- nb Local w/AR
netbuilderLocalSn OBJECT IDENTIFIER ::= { netbuilderLocal 7 } -- nb Local w/SN
netbuilderLocalRb OBJECT IDENTIFIER ::= { netbuilderLocal 8 } -- nb Local w/RB
netbuilderLocalFf OBJECT IDENTIFIER ::= { netbuilderLocal 9 } -- nb Local w/FF
netbuilderLocalCf OBJECT IDENTIFIER ::= { netbuilderLocal 10 } -- nb Local w/CF
netbuilderLocalBx OBJECT IDENTIFIER ::= { netbuilderLocal 11 } -- nb Local w/BX
netbuilderLocalAppn OBJECT IDENTIFIER ::= { netbuilderLocal 12 } -- nb Local w/Appn SW
netbuilderLocalLm OBJECT IDENTIFIER ::= { netbuilderLocal 13 } -- nb Local w/Lm
netbuilderLocalLt OBJECT IDENTIFIER ::= { netbuilderLocal 14 } -- nb Local w/Lt
netbuilderLocalWm OBJECT IDENTIFIER ::= { netbuilderLocal 15 } -- nb Local w/Wm
netbuilderLocalWt OBJECT IDENTIFIER ::= { netbuilderLocal 16 } -- nb Local w/Wt
netbuilderLocalAe OBJECT IDENTIFIER ::= { netbuilderLocal 17 } -- nb Local w/Ae
netbuilderLocalAp OBJECT IDENTIFIER ::= { netbuilderLocal 18 } -- nb Local w/Ap
netbuilderLocalAn OBJECT IDENTIFIER ::= { netbuilderLocal 19 } -- nb Local w/An
netbuilderLocalLa OBJECT IDENTIFIER ::= { netbuilderLocal 20 } -- nb Local w/La
netbuilderLocalWa OBJECT IDENTIFIER ::= { netbuilderLocal 21 } -- nb Local w/Wa
netbuilderLocalAa OBJECT IDENTIFIER ::= { netbuilderLocal 22 } -- nb Local w/Aa
netbuilderLocalAb OBJECT IDENTIFIER ::= { netbuilderLocal 23 } -- nb Local w/Ab
netbuilderLocalBf OBJECT IDENTIFIER ::= { netbuilderLocal 24 } -- nb Local w/Bf
--
-- the following identifiers are assigned under a3Com.products.brouter.netbuilderTrLocal
--
netbuilderTrLocalBp OBJECT IDENTIFIER ::= { netbuilderTrLocal 1 } -- nbtr Local w/Basic Prot SW
netbuilderTrLocalCp OBJECT IDENTIFIER ::= { netbuilderTrLocal 2 } -- nbtr Local w/Compl Prot SW
netbuilderTrLocalXw OBJECT IDENTIFIER ::= { netbuilderTrLocal 3 } -- nbtr Local w/XW
netbuilderTrLocalCx OBJECT IDENTIFIER ::= { netbuilderTrLocal 4 } -- nbtr Local w/CX
netbuilderTrLocalBa OBJECT IDENTIFIER ::= { netbuilderTrLocal 5 } -- nbtr Local w/BA
netbuilderTrLocalAr OBJECT IDENTIFIER ::= { netbuilderTrLocal 6 } -- nbtr Local w/Acc Rtr SW
netbuilderTrLocalSn OBJECT IDENTIFIER ::= { netbuilderTrLocal 7 } -- nbtr Local w/SNA Acc Rtr SW
netbuilderTrLocalRb OBJECT IDENTIFIER ::= { netbuilderTrLocal 8 } -- nbtr Local w/RB
netbuilderTrLocalFf OBJECT IDENTIFIER ::= { netbuilderTrLocal 9 } -- nbtr Local w/FF
netbuilderTrLocalCf OBJECT IDENTIFIER ::= { netbuilderTrLocal 10 } -- nbtr Local w/CF
netbuilderTrLocalBx OBJECT IDENTIFIER ::= { netbuilderTrLocal 11 } -- nbtr Local w/BX SW
netbuilderTrLocalAppn OBJECT IDENTIFIER ::= { netbuilderTrLocal 12 } -- nb TrLocal w/Appn SW
netbuilderTrLocalLm OBJECT IDENTIFIER ::= { netbuilderTrLocal 13 } -- nbtr Local w/Lm
netbuilderTrLocalLt OBJECT IDENTIFIER ::= { netbuilderTrLocal 14 } -- nbtr Local w/Lt
netbuilderTrLocalWm OBJECT IDENTIFIER ::= { netbuilderTrLocal 15 } -- nbtr Local w/Wm
netbuilderTrLocalWt OBJECT IDENTIFIER ::= { netbuilderTrLocal 16 } -- nbtr Local w/Wt
netbuilderTrLocalAe OBJECT IDENTIFIER ::= { netbuilderTrLocal 17 } -- nbtr Local w/Ae
netbuilderTrLocalAp OBJECT IDENTIFIER ::= { netbuilderTrLocal 18 } -- nbtr Local w/Ap
netbuilderTrLocalAn OBJECT IDENTIFIER ::= { netbuilderTrLocal 19 } -- nbtr Local w/An
netbuilderTrLocalLa OBJECT IDENTIFIER ::= { netbuilderTrLocal 20 } -- nbtr Local w/La
netbuilderTrLocalWa OBJECT IDENTIFIER ::= { netbuilderTrLocal 21 } -- nbtr Local w/Wa
netbuilderTrLocalAa OBJECT IDENTIFIER ::= { netbuilderTrLocal 22 } -- nbtr Local w/Aa
netbuilderTrLocalAb OBJECT IDENTIFIER ::= { netbuilderTrLocal 23 } -- nbtr Local w/Ab
netbuilderTrLocalBf OBJECT IDENTIFIER ::= { netbuilderTrLocal 24 } -- nbtr Local w/Bf
--
-- the following identifiers are assigned under a3Com.products.brouter.netbuilderRC1x2
--
netbuilderRC1x2bp OBJECT IDENTIFIER ::= { netbuilderRC1x2 1 } -- nbRC1x2 w/BP
netbuilderRC1x2cp OBJECT IDENTIFIER ::= { netbuilderRC1x2 2 } -- nbRC1x2 w/CP
netbuilderRC1x2xw OBJECT IDENTIFIER ::= { netbuilderRC1x2 3 } -- nbRC1x2 w/XW
netbuilderRC1x2cx OBJECT IDENTIFIER ::= { netbuilderRC1x2 4 } -- nbRC1x2 w/CX
netbuilderRC1x2ba OBJECT IDENTIFIER ::= { netbuilderRC1x2 5 } -- nbRC1x2 w/BA
netbuilderRC1x2ar OBJECT IDENTIFIER ::= { netbuilderRC1x2 6 } -- nb RC1x2 w/AR
netbuilderRC1x2sn OBJECT IDENTIFIER ::= { netbuilderRC1x2 7 } -- nb RC1x2 w/SN
netbuilderRC1x2rb OBJECT IDENTIFIER ::= { netbuilderRC1x2 8 } -- nb RC1x2 w/RB
netbuilderRC1x2ff OBJECT IDENTIFIER ::= { netbuilderRC1x2 9 } -- nb RC1x2 w/FF
netbuilderRC1x2cf OBJECT IDENTIFIER ::= { netbuilderRC1x2 10 } -- nb RC1x2 w/CF
netbuilderRC1x2bx OBJECT IDENTIFIER ::= { netbuilderRC1x2 11 } -- nb RC1x2 w/BX
netbuilderRC1x2appn OBJECT IDENTIFIER ::= { netbuilderRC1x2 12 } -- RC1x2 w/Appn
netbuilderRC1x2lm OBJECT IDENTIFIER ::= { netbuilderRC1x2 13 } -- RC1x2 w/Lm
netbuilderRC1x2lt OBJECT IDENTIFIER ::= { netbuilderRC1x2 14 } -- RC1x2 w/Lt Sw
netbuilderRC1x2wm OBJECT IDENTIFIER ::= { netbuilderRC1x2 15 } -- RC1x2 w/Wm Sw
netbuilderRC1x2wt OBJECT IDENTIFIER ::= { netbuilderRC1x2 16 } -- RC1x2 w/Wt Sw
netbuilderRC1x2ae OBJECT IDENTIFIER ::= { netbuilderRC1x2 17 } -- RC1x2 w/Ae Sw
netbuilderRC1x2ap OBJECT IDENTIFIER ::= { netbuilderRC1x2 18 } -- RC1x2 w/Ap Sw
netbuilderRC1x2an OBJECT IDENTIFIER ::= { netbuilderRC1x2 19 } -- RC1x2 w/An Sw
netbuilderRC1x2la OBJECT IDENTIFIER ::= { netbuilderRC1x2 20 } -- RC1x2 w/La Sw
netbuilderRC1x2wa OBJECT IDENTIFIER ::= { netbuilderRC1x2 21 } -- RC1x2 w/Wa Sw
netbuilderRC1x2aa OBJECT IDENTIFIER ::= { netbuilderRC1x2 22 } -- RC1x2 w/Aa Sw
netbuilderRC1x2ab OBJECT IDENTIFIER ::= { netbuilderRC1x2 23 } -- RC1x2 w/Ab Sw
netbuilderRC1x2bf OBJECT IDENTIFIER ::= { netbuilderRC1x2 24 } -- RC1x2 w/Bf Sw
--
-- the following identifiers are assigned under a3Com.products.brouter.netbuilderTrRC1x2
--
netbuilderTrRC1x2bp OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 1 }
netbuilderTrRC1x2cp OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 2 }
netbuilderTrRC1x2xw OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 3 }
netbuilderTrRC1x2cx OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 4 }
netbuilderTrRC1x2ba OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 5 }
netbuilderTrRC1x2ar OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 6 }
netbuilderTrRC1x2sn OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 7 }
netbuilderTrRC1x2rb OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 8 }
netbuilderTrRC1x2ff OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 9 }
netbuilderTrRC1x2cf OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 10 }
netbuilderTrRC1x2bx OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 11 }
netbuilderTrRC1x2appn OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 12 }
netbuilderTrRC1x2lm OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 13 }
netbuilderTrRC1x2lt OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 14 }
netbuilderTrRC1x2wm OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 15 }
netbuilderTrRC1x2wt OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 16 }
netbuilderTrRC1x2ae OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 17 }
netbuilderTrRC1x2ap OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 18 }
netbuilderTrRC1x2an OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 19 }
netbuilderTrRC1x2la OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 20 }
netbuilderTrRC1x2wa OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 21 }
netbuilderTrRC1x2aa OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 22 }
netbuilderTrRC1x2ab OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 23 }
netbuilderTrRC1x2bf OBJECT IDENTIFIER ::= { netbuilderTrRC1x2 24 }
--
-- the following identifiers are assigned under a3Com.products.brouter.casper
-- (casper aka "nbro Large" )
--
nbrolBp OBJECT IDENTIFIER ::= { casper 1 } -- casper w/Basic Prot SW
nbrolCp OBJECT IDENTIFIER ::= { casper 2 } -- casper w/Compl Prot SW
nbrolXw OBJECT IDENTIFIER ::= { casper 3 } -- casper w/Ext WAN SW
nbrol228 OBJECT IDENTIFIER ::= { casper 4 } -- casper w/Conn Svc SW
nbrol201 OBJECT IDENTIFIER ::= { casper 5 } -- casper w/Bndry Rtg. SW
nbro222 OBJECT IDENTIFIER ::= { casper 6 } -- casper w/AR SW
nbrolSn OBJECT IDENTIFIER ::= { casper 7 } -- casper w/SNA
nbrol200 OBJECT IDENTIFIER ::= { casper 8 } -- casper w/RB. SW
nbrolFf OBJECT IDENTIFIER ::= { casper 9 } -- casper w/Full Feature SW
nbro227 OBJECT IDENTIFIER ::= { casper 10 } -- casper w/CF SW
nbro221 OBJECT IDENTIFIER ::= { casper 11 } -- casper w/BX SW
nbrolAppn OBJECT IDENTIFIER ::= { casper 12 } -- casper w/Appn SW
nbrolLm OBJECT IDENTIFIER ::= { casper 13 } -- casper w/Lm Sw
nbrolLt OBJECT IDENTIFIER ::= { casper 14 } -- casper w/Lt Sw
nbrolWm OBJECT IDENTIFIER ::= { casper 15 } -- casper w/Wm Sw
nbrolWt OBJECT IDENTIFIER ::= { casper 16 } -- casper w/Wt Sw
nbrolAe OBJECT IDENTIFIER ::= { casper 17 } -- casper w/Ae Sw
nbrolAp OBJECT IDENTIFIER ::= { casper 18 } -- casper w/Ap Sw
nbrolAn OBJECT IDENTIFIER ::= { casper 19 } -- casper w/An Sw
nbrolLa OBJECT IDENTIFIER ::= { casper 20 } -- casper w/La Sw
nbrolWa OBJECT IDENTIFIER ::= { casper 21 } -- casper w/Wa Sw
nbrol224 OBJECT IDENTIFIER ::= { casper 22 } -- casper w/Aa Sw
nbrolAb OBJECT IDENTIFIER ::= { casper 23 } -- casper w/Ab Sw
nbrol223 OBJECT IDENTIFIER ::= { casper 24 } -- casper w/Bf Sw
--
-- the following identifiers are assigned under a3Com.products.brouter.spectreHuge
-- (spectre Huge aka nbro Huge )
--
nbrohBp OBJECT IDENTIFIER ::= { spectreHuge 1 } -- spectreHuge w/BP SW
nbrohCp OBJECT IDENTIFIER ::= { spectreHuge 2 } -- spectreHuge w/CP SW
nbrohXw OBJECT IDENTIFIER ::= { spectreHuge 3 } -- spectreHuge w/Ext WAN SW
nbro228 OBJECT IDENTIFIER ::= { spectreHuge 4 } -- spectreHuge w/CX SW
nbroh201 OBJECT IDENTIFIER ::= { spectreHuge 5 } -- casper w/Bndry Rtg. SW
nbroh222 OBJECT IDENTIFIER ::= { spectreHuge 6 } -- spectreHuge w/AR SW
nbrohSn OBJECT IDENTIFIER ::= { spectreHuge 7 } -- spectreHuge w/SNA
nbroh200 OBJECT IDENTIFIER ::= { spectreHuge 8 } -- spectreHuge w/RB SW
nbrohFf OBJECT IDENTIFIER ::= { spectreHuge 9 } -- spectreHuge w/FF SW
nbroh227 OBJECT IDENTIFIER ::= { spectreHuge 10 } -- spectreHuge w/CF SW
nbroh221 OBJECT IDENTIFIER ::= { spectreHuge 11 } -- spectreHuge w/BX SW
nbrohAppn OBJECT IDENTIFIER ::= { spectreHuge 12 } -- spectreHuge w/Appn SW
nbrohLm OBJECT IDENTIFIER ::= { spectreHuge 13 } -- spectreHuge w/Lm Sw
nbrohLt OBJECT IDENTIFIER ::= { spectreHuge 14 } -- spectreHuge w/Lt Sw
nbrohWm OBJECT IDENTIFIER ::= { spectreHuge 15 } -- spectreHuge w/Wm Sw
nbrohWt OBJECT IDENTIFIER ::= { spectreHuge 16 } -- spectreHuge w/Wt Sw
nbrohAe OBJECT IDENTIFIER ::= { spectreHuge 17 } -- spectreHuge w/Ae Sw
nbrohAp OBJECT IDENTIFIER ::= { spectreHuge 18 } -- spectreHuge w/Ap Sw
nbrohAn OBJECT IDENTIFIER ::= { spectreHuge 19 } -- spectreHuge w/An Sw
nbrohLa OBJECT IDENTIFIER ::= { spectreHuge 20 } -- spectreHuge w/La Sw
nbrohWa OBJECT IDENTIFIER ::= { spectreHuge 21 } -- spectreHuge w/Wa Sw
nbroh224 OBJECT IDENTIFIER ::= { spectreHuge 22 } -- spectreHuge w/Aa Sw
nbrohAb OBJECT IDENTIFIER ::= { spectreHuge 23 } -- spectreHuge w/Ab Sw
nbroh223 OBJECT IDENTIFIER ::= { spectreHuge 24 } -- spectreHuge w/Bf Sw
--
-- the following identifiers are assigned under a3Com.products.brouter.spectreIsdn
--
nbroiBp OBJECT IDENTIFIER ::= { spectreIsdn 1 } -- spectreIsdn w/BP SW
nbroiCp OBJECT IDENTIFIER ::= { spectreIsdn 2 } -- spectreIsdn w/CP SW
nbroiXw OBJECT IDENTIFIER ::= { spectreIsdn 3 } -- spectreIsdn w/Ext WAN SW
nbroiCX OBJECT IDENTIFIER ::= { spectreIsdn 4 } -- spectreIsdn w/CX SW
nbroiBA OBJECT IDENTIFIER ::= { spectreIsdn 5 } -- spectreIsdn w/Bndry Rtg. SW
nbro422 OBJECT IDENTIFIER ::= { spectreIsdn 6 } -- spectreIsdn w/AR SW
nbroiSn OBJECT IDENTIFIER ::= { spectreIsdn 7 } -- spectreIsdn w/SNA
nbroi200 OBJECT IDENTIFIER ::= { spectreIsdn 8 } -- spectreIsdn w/RB SW
nbroiFf OBJECT IDENTIFIER ::= { spectreIsdn 9 } -- spectreIsdn w/FF SW
nbroil427 OBJECT IDENTIFIER ::= { spectreIsdn 10 } -- spectreIsdn w/CF SW
nbro421 OBJECT IDENTIFIER ::= { spectreIsdn 11 } -- spectreIsdn w/BX SW
nbroiAppn OBJECT IDENTIFIER ::= { spectreIsdn 12 } -- spectreIsdn w/Appn SW
nbroiLm OBJECT IDENTIFIER ::= { spectreIsdn 13 } -- spectreIsdn w/Lm Sw
nbroiLt OBJECT IDENTIFIER ::= { spectreIsdn 14 } -- spectreIsdn w/Lt Sw
nbroiWm OBJECT IDENTIFIER ::= { spectreIsdn 15 } -- spectreIsdn w/Wm Sw
nbroiWt OBJECT IDENTIFIER ::= { spectreIsdn 16 } -- spectreIsdn w/Wt Sw
nbroiAe OBJECT IDENTIFIER ::= { spectreIsdn 17 } -- spectreIsdn w/Ae Sw
nbroiAp OBJECT IDENTIFIER ::= { spectreIsdn 18 } -- spectreIsdn w/Ap Sw
nbroiAn OBJECT IDENTIFIER ::= { spectreIsdn 19 } -- spectreIsdn w/An Sw
nbroiLa OBJECT IDENTIFIER ::= { spectreIsdn 20 } -- spectreIsdn w/La Sw
nbroiWa OBJECT IDENTIFIER ::= { spectreIsdn 21 } -- spectreIsdn w/Wa Sw
nbroi424 OBJECT IDENTIFIER ::= { spectreIsdn 22 } -- spectreIsdn w/Aa Sw
nbroiAb OBJECT IDENTIFIER ::= { spectreIsdn 23 } -- spectreIsdn w/Ab Sw
nbroi423 OBJECT IDENTIFIER ::= { spectreIsdn 24 } -- spectreIsdn w/Bf Sw
--
-- the following identifiers are assigned under a3Com.products.brouter.nb2_8_4fddi
--
nb2-8-4fddiBp OBJECT IDENTIFIER ::= { nb2-8-4fddi 1 } -- crew 4fddi w/BP
nb2-8-4fddiCp OBJECT IDENTIFIER ::= { nb2-8-4fddi 2 } -- crew 4fddi w/CP
nb2-8-4fddiXw OBJECT IDENTIFIER ::= { nb2-8-4fddi 3 } -- crew 4fddi w/XW
nb2-8-4fddiCx OBJECT IDENTIFIER ::= { nb2-8-4fddi 4 } -- crew 4fddi w/CX
nb2-8-4fddiBa OBJECT IDENTIFIER ::= { nb2-8-4fddi 5 } -- crew 4fddi w/BA
nb2-8-4fddiAr OBJECT IDENTIFIER ::= { nb2-8-4fddi 6 } -- crew 4fddi w/AR
nb2-8-4fddiSn OBJECT IDENTIFIER ::= { nb2-8-4fddi 7 } -- crew 4fddi w/SNA
nb2-8-4fddiRb OBJECT IDENTIFIER ::= { nb2-8-4fddi 8 } -- crew 4fddi w/RB
nb2-8-4fddiFf OBJECT IDENTIFIER ::= { nb2-8-4fddi 9 } -- crew 4fddi w/FF
nb2-8-4fddiCf OBJECT IDENTIFIER ::= { nb2-8-4fddi 10 } -- crew 4fddi w/CF
nb2-8-4fddiBx OBJECT IDENTIFIER ::= { nb2-8-4fddi 11 } -- crew 4fddi w/BX
nb2-8-4fddiAppn OBJECT IDENTIFIER ::= { nb2-8-4fddi 12 } -- crew 4fddi w/Appn
nb2-8-4fddiLm OBJECT IDENTIFIER ::= { nb2-8-4fddi 13 } -- crew 4fddi w/Lm
nb2-8-4fddiLt OBJECT IDENTIFIER ::= { nb2-8-4fddi 14 } -- crew 4fddi w/Lt
nb2-8-4fddiWm OBJECT IDENTIFIER ::= { nb2-8-4fddi 15 } -- crew 4fddi w/Wm
nb2-8-4fddiWt OBJECT IDENTIFIER ::= { nb2-8-4fddi 16 } -- crew 4fddi w/Wt
nb2-8-4fddiAe OBJECT IDENTIFIER ::= { nb2-8-4fddi 17 } -- crew 4fddi w/Ae
nb2-8-4fddiAp OBJECT IDENTIFIER ::= { nb2-8-4fddi 18 } -- crew 4fddi w/Ap
nb2-8-4fddiAn OBJECT IDENTIFIER ::= { nb2-8-4fddi 19 } -- crew 4fddi w/An
nb2-8-4fddiLa OBJECT IDENTIFIER ::= { nb2-8-4fddi 20 } -- crew 4fddi w/La
nb2-8-4fddiWa OBJECT IDENTIFIER ::= { nb2-8-4fddi 21 } -- crew 4fddi w/Wa
nb2-8-4fddiAa OBJECT IDENTIFIER ::= { nb2-8-4fddi 22 } -- crew 4fddi w/Aa
nb2-8-4fddiAb OBJECT IDENTIFIER ::= { nb2-8-4fddi 23 } -- crew 4fddi w/Ab
nb2-8-4fddiBf OBJECT IDENTIFIER ::= { nb2-8-4fddi 24 } -- crew 4fddi w/Bf
--
-- the following identifiers are assigned under a3Com.products.brouter.nb2_8_dualwide
--
nb2-8-dualwideBp OBJECT IDENTIFIER ::= { nb2-8-dualwide 1 } -- crew dualwide w/BP
nb2-8-dualwideCp OBJECT IDENTIFIER ::= { nb2-8-dualwide 2 } -- crew dualwide w/CP
nb2-8-dualwideXw OBJECT IDENTIFIER ::= { nb2-8-dualwide 3 } -- crew dualwide w/XW
nb2-8-dualwideCx OBJECT IDENTIFIER ::= { nb2-8-dualwide 4 } -- crew dualwide w/CX
nb2-8-dualwideBa OBJECT IDENTIFIER ::= { nb2-8-dualwide 5 } -- crew dualwide w/BA
nb2-8-dualwideAr OBJECT IDENTIFIER ::= { nb2-8-dualwide 6 } -- crew dualwide w/AR
nb2-8-dualwideSn OBJECT IDENTIFIER ::= { nb2-8-dualwide 7 } -- crew dualwide w/SNA
nb2-8-dualwideRb OBJECT IDENTIFIER ::= { nb2-8-dualwide 8 } -- crew dualwide w/RB
nb2-8-dualwideFf OBJECT IDENTIFIER ::= { nb2-8-dualwide 9 } -- crew dualwide w/FF
nb2-8-dualwideCf OBJECT IDENTIFIER ::= { nb2-8-dualwide 10 } -- crew dualwide w/CF
nb2-8-dualwideBx OBJECT IDENTIFIER ::= { nb2-8-dualwide 11 } -- crew dualwide w/BX
nb2-8-dualwideAppn OBJECT IDENTIFIER ::= { nb2-8-dualwide 12 } -- crew dualwide w/Appn
nb2-8-dualwideLm OBJECT IDENTIFIER ::= { nb2-8-dualwide 13 } -- crew dualwide w/Lm
nb2-8-dualwideLt OBJECT IDENTIFIER ::= { nb2-8-dualwide 14 } -- crew dualwide w/Lt
nb2-8-dualwideWm OBJECT IDENTIFIER ::= { nb2-8-dualwide 15 } -- crew dualwide w/Wm
nb2-8-dualwideWt OBJECT IDENTIFIER ::= { nb2-8-dualwide 16 } -- crew dualwide w/Wt
nb2-8-dualwideAe OBJECT IDENTIFIER ::= { nb2-8-dualwide 17 } -- crew dualwide w/Ae
nb2-8-dualwideAp OBJECT IDENTIFIER ::= { nb2-8-dualwide 18 } -- crew dualwide w/Ap
nb2-8-dualwideAn OBJECT IDENTIFIER ::= { nb2-8-dualwide 19 } -- crew dualwide w/An
nb2-8-dualwideLa OBJECT IDENTIFIER ::= { nb2-8-dualwide 20 } -- crew dualwide w/La
nb2-8-dualwideWa OBJECT IDENTIFIER ::= { nb2-8-dualwide 21 } -- crew dualwide w/Wa
nb2-8-dualwideAa OBJECT IDENTIFIER ::= { nb2-8-dualwide 22 } -- crew dualwide w/Aa
nb2-8-dualwideAb OBJECT IDENTIFIER ::= { nb2-8-dualwide 23 } -- crew dualwide w/Ab
nb2-8-dualwideBf OBJECT IDENTIFIER ::= { nb2-8-dualwide 24 } -- crew dualwide w/Bf
--
-- the following identifiers are assigned under a3Com.products.brouter.spectreIs dnHuge
--
nbroihBp OBJECT IDENTIFIER ::= { spectreIsdnHuge 1 } --spectreIsdn w/BP SW
nbroihCp OBJECT IDENTIFIER ::= { spectreIsdnHuge 2 } --spectreIsdn w/CP SW
nbroihXw OBJECT IDENTIFIER ::= { spectreIsdnHuge 3 } -- spectreIsdn w/Ext WAN SW
nbroihCx OBJECT IDENTIFIER ::= { spectreIsdnHuge 4 } -- spectreIsdn w/CX SW
nbroihBa OBJECT IDENTIFIER ::= { spectreIsdnHuge 5 } --spectreIsdn w/Bndry Rtg . SW
nbroih422 OBJECT IDENTIFIER ::= { spectreIsdnHuge 6 } --spectreIsdn w/AR SW
nbroihSn OBJECT IDENTIFIER ::= { spectreIsdnHuge 7 } --spectreIsdn w/SNA
nbroihRb OBJECT IDENTIFIER ::= { spectreIsdnHuge 8 } --spectreIsdn w/RB SW
nbroihFf OBJECT IDENTIFIER ::= { spectreIsdnHuge 9 } -- spectreIsdn w/FF SW
nbroih427 OBJECT IDENTIFIER ::= { spectreIsdnHuge 10 }--spectreIsdn w/CF SW
nbroih421 OBJECT IDENTIFIER ::= { spectreIsdnHuge 11 }--spectreIsdn w/BX SW
nbroihAppn OBJECT IDENTIFIER ::= { spectreIsdnHuge 12 } -- spectreIsdn w/Appn
nbroihLm OBJECT IDENTIFIER ::= { spectreIsdnHuge 13 } -- spectreIsdn w/Lm Sw
nbroihLt OBJECT IDENTIFIER ::= { spectreIsdnHuge 14 } -- spectreIsdn w/Lt Sw
nbroihWm OBJECT IDENTIFIER ::= { spectreIsdnHuge 15 } -- spectreIsdn w/Wm Sw
nbroihWt OBJECT IDENTIFIER ::= { spectreIsdnHuge 16 } -- spectreIsdn w/Wt Sw
nbroihAe OBJECT IDENTIFIER ::= { spectreIsdnHuge 17 } -- spectreIsdn w/Ae Sw
nbroihAp OBJECT IDENTIFIER ::= { spectreIsdnHuge 18 } -- spectreIsdn w/Ap Sw
nbroihAn OBJECT IDENTIFIER ::= { spectreIsdnHuge 19 } -- spectreIsdn w/An Sw
nbroihLa OBJECT IDENTIFIER ::= { spectreIsdnHuge 20 } -- spectreIsdn w/La Sw
nbroihWa OBJECT IDENTIFIER ::= { spectreIsdnHuge 21 } -- spectreIsdn w/Wa Sw
nbroih424 OBJECT IDENTIFIER ::= { spectreIsdnHuge 22 } -- spectreIsdn w/Aa Sw
nbroihAb OBJECT IDENTIFIER ::= { spectreIsdnHuge 23 } -- spectreIsdn w/Ab Sw
nbroih423 OBJECT IDENTIFIER ::= { spectreIsdnHuge 24 } -- spectreIsdn w/Bf Sw
--
-- the following identifiers are assigned under a3Com.products.brouter.nbroTrLarge
--
nbroTrlBp OBJECT IDENTIFIER ::= { nbroTrLarge 1 } --nbroTrLarge w/BP SW
nbroTrlCp OBJECT IDENTIFIER ::= { nbroTrLarge 2 } --nbroTrLarge w/CP SW
nbroTrlXw OBJECT IDENTIFIER ::= { nbroTrLarge 3 } -- nbroTrLarge w/Ext WAN SW
nbroTrlCx OBJECT IDENTIFIER ::= { nbroTrLarge 4 } -- nbroTrLarge w/CX SW
nbroTrlBa OBJECT IDENTIFIER ::= { nbroTrLarge 5 } --nbroTrLarge w/Bndry Rtg. SW
nbro322 OBJECT IDENTIFIER ::= { nbroTrLarge 6 } --nbroTrLarge w/AR SW
nbroTrlSn OBJECT IDENTIFIER ::= { nbroTrLarge 7 } --nbroTrLarge w/SNA
nbroTrlRb OBJECT IDENTIFIER ::= { nbroTrLarge 8 } --nbroTrLarge w/RB SW
nbroTrlFf OBJECT IDENTIFIER ::= { nbroTrLarge 9 } -- nbroTrLarge w/FF SW
nbroTrl327 OBJECT IDENTIFIER ::= { nbroTrLarge 10 }--nbroTrLarge w/CF SW
nbro321 OBJECT IDENTIFIER ::= { nbroTrLarge 11 }--nbroTrLarge w/BX SW
nbroTrlAppn OBJECT IDENTIFIER ::= { nbroTrLarge 12 } -- nbroTrLarge w/Appn SW
nbroTrlLm OBJECT IDENTIFIER ::= { nbroTrLarge 13 } -- nbroTrLarge w/Lm Sw
nbroTrlLt OBJECT IDENTIFIER ::= { nbroTrLarge 14 } -- nbroTrLarge w/Lt Sw
nbroTrlWm OBJECT IDENTIFIER ::= { nbroTrLarge 15 } -- nbroTrLarge w/Wm Sw
nbroTrlWt OBJECT IDENTIFIER ::= { nbroTrLarge 16 } -- nbroTrLarge w/Wt Sw
nbroTrlAe OBJECT IDENTIFIER ::= { nbroTrLarge 17 } -- nbroTrLarge w/Ae Sw
nbroTrlAp OBJECT IDENTIFIER ::= { nbroTrLarge 18 } -- nbroTrLarge w/Ap Sw
nbroTrlAn OBJECT IDENTIFIER ::= { nbroTrLarge 19 } -- nbroTrLarge w/An Sw
nbroTrlLa OBJECT IDENTIFIER ::= { nbroTrLarge 20 } -- nbroTrLarge w/La Sw
nbroTrlWa OBJECT IDENTIFIER ::= { nbroTrLarge 21 } -- nbroTrLarge w/Wa Sw
nbroTrlAa OBJECT IDENTIFIER ::= { nbroTrLarge 22 } -- nbroTrLarge w/Aa Sw
nbroTrlAb OBJECT IDENTIFIER ::= { nbroTrLarge 23 } -- nbroTrLarge w/Ab Sw
nbroTrl323 OBJECT IDENTIFIER ::= { nbroTrLarge 24 } -- nbroTrLarge w/Bf Sw
--
-- the following identifiers are assigned under a3Com.products.brouter.nbroTrIsdn
--
nbroTrIsdnBp OBJECT IDENTIFIER ::= { nbroTrIsdn 1 } --nbroTrIsdn w/BP SW
nbroTrIsdnCp OBJECT IDENTIFIER ::= { nbroTrIsdn 2 } --nbroTrIsdn w/CP SW
nbroTrIsdnXw OBJECT IDENTIFIER ::= { nbroTrIsdn 3 } -- nbroTrIsdn w/Ext WAN SW
nbroTrIsdnCx OBJECT IDENTIFIER ::= { nbroTrIsdn 4 } -- nbroTrIsdn w/CX SW
nbroTrIsdnBa OBJECT IDENTIFIER ::= { nbroTrIsdn 5 } --nbroTrIsdn w/Bndry Rtg. SW
nbroTrIsdnAr OBJECT IDENTIFIER ::= { nbroTrIsdn 6 } --nbroTrIsdn w/AR SW
nbroTrIsdnSn OBJECT IDENTIFIER ::= { nbroTrIsdn 7 } --nbroTrIsdn w/SNA
nbroTrIsdnRb OBJECT IDENTIFIER ::= { nbroTrIsdn 8 } --nbroTrIsdn w/RB SW
nbroTrIsdnFf OBJECT IDENTIFIER ::= { nbroTrIsdn 9 } -- nbroTrIsdn w/FF SW
nbro527 OBJECT IDENTIFIER ::= { nbroTrIsdn 10 }--nbroTrIsdn w/CF SW
nbroTrIsdnBx OBJECT IDENTIFIER ::= { nbroTrIsdn 11 }--nbroTrIsdn w/BX SW
nbroTrIsdnAppn OBJECT IDENTIFIER ::= { nbroTrIsdn 12 } -- nbroTrIsdn w/Appn SW
nbroTrIsdnLm OBJECT IDENTIFIER ::= { nbroTrIsdn 13 } -- nbroTrIsdn w/Lm Sw
nbroTrIsdnLt OBJECT IDENTIFIER ::= { nbroTrIsdn 14 } -- nbroTrIsdn w/Lt Sw
nbroTrIsdnWm OBJECT IDENTIFIER ::= { nbroTrIsdn 15 } -- nbroTrIsdn w/Wm Sw
nbroTrIsdnWt OBJECT IDENTIFIER ::= { nbroTrIsdn 16 } -- nbroTrIsdn w/Wt Sw
nbroTrIsdnAe OBJECT IDENTIFIER ::= { nbroTrIsdn 17 } -- nbroTrIsdn w/Ae Sw
nbroTrIsdnAp OBJECT IDENTIFIER ::= { nbroTrIsdn 18 } -- nbroTrIsdn w/Ap Sw
nbroTrIsdnAn OBJECT IDENTIFIER ::= { nbroTrIsdn 19 } -- nbroTrIsdn w/An Sw
nbroTrIsdnLa OBJECT IDENTIFIER ::= { nbroTrIsdn 20 } -- nbroTrIsdn w/La Sw
nbroTrIsdnWa OBJECT IDENTIFIER ::= { nbroTrIsdn 21 } -- nbroTrIsdn w/Wa Sw
nbroTrIsdnAa OBJECT IDENTIFIER ::= { nbroTrIsdn 22 } -- nbroTrIsdn w/Aa Sw
nbroTrIsdnAb OBJECT IDENTIFIER ::= { nbroTrIsdn 23 } -- nbroTrIsdn w/Ab Sw
nbro523 OBJECT IDENTIFIER ::= { nbroTrIsdn 24 } -- nbroTrIsdn w/Bf Sw
--
-- the following identifiers are assigned under a3Com.products.brouter.nbroTrHuge
--
nbroTrhBp OBJECT IDENTIFIER ::= { nbroTrHuge 1 } --nbroTrHuge w/BP SW
nbroTrhCp OBJECT IDENTIFIER ::= { nbroTrHuge 2 } --nbroTrHuge w/CP SW
nbroTrhXw OBJECT IDENTIFIER ::= { nbroTrHuge 3 } -- nbroTrHuge w/Ext WAN SW
nbroTrhCx OBJECT IDENTIFIER ::= { nbroTrHuge 4 } -- nbroTrHuge w/CX SW
nbroTrhBa OBJECT IDENTIFIER ::= { nbroTrHuge 5 } --nbroTrHuge w/Bndry Rtg. SW
nbroTrh322 OBJECT IDENTIFIER ::= { nbroTrHuge 6 } --nbroTrHuge w/AR SW
nbroTrhSn OBJECT IDENTIFIER ::= { nbroTrHuge 7 } --nbroTrHuge w/SNA
nbroTrhRb OBJECT IDENTIFIER ::= { nbroTrHuge 8 } --nbroTrHuge w/RB SW
nbroTrhFf OBJECT IDENTIFIER ::= { nbroTrHuge 9 } -- nbroTrHuge w/FF SW
nbroTrh327 OBJECT IDENTIFIER ::= { nbroTrHuge 10 }--nbroTrHuge w/CF SW
nbroTrh321 OBJECT IDENTIFIER ::= { nbroTrHuge 11 }--nbroTrHuge w/BX SW
nbroTrhAppn OBJECT IDENTIFIER ::= { nbroTrHuge 12 } -- nbroTrHuge w/Appn SW
nbroTrhLm OBJECT IDENTIFIER ::= { nbroTrHuge 13 } -- nbroTrHuge w/Lm Sw
nbroTrhLt OBJECT IDENTIFIER ::= { nbroTrHuge 14 } -- nbroTrHuge w/Lt Sw
nbroTrhWm OBJECT IDENTIFIER ::= { nbroTrHuge 15 } -- nbroTrHuge w/Wm Sw
nbroTrhWt OBJECT IDENTIFIER ::= { nbroTrHuge 16 } -- nbroTrHuge w/Wt Sw
nbroTrhAe OBJECT IDENTIFIER ::= { nbroTrHuge 17 } -- nbroTrHuge w/Ae Sw
nbroTrhAp OBJECT IDENTIFIER ::= { nbroTrHuge 18 } -- nbroTrHuge w/Ap Sw
nbroTrhAn OBJECT IDENTIFIER ::= { nbroTrHuge 19 } -- nbroTrHuge w/An Sw
nbroTrhLa OBJECT IDENTIFIER ::= { nbroTrHuge 20 } -- nbroTrHuge w/La Sw
nbroTrhWa OBJECT IDENTIFIER ::= { nbroTrHuge 21 } -- nbroTrHuge w/Wa Sw
nbroTrhAa OBJECT IDENTIFIER ::= { nbroTrHuge 22 } -- nbroTrHuge w/Aa Sw
nbroTrhAb OBJECT IDENTIFIER ::= { nbroTrHuge 23 } -- nbroTrHuge w/Ab Sw
nbroTrh323 OBJECT IDENTIFIER ::= { nbroTrHuge 24 } -- nbroTrHuge w/Bf Sw
--
-- the following identifiers are assigned under a3Com.products.brouter.officeConnRtr
--
ocRtrBp OBJECT IDENTIFIER ::= { officeConnRtr 1 } --officeConnRtr w/BP SW
ocRtrCp OBJECT IDENTIFIER ::= { officeConnRtr 2 } --officeConnRtr w/CP SW
ocRtrXw OBJECT IDENTIFIER ::= { officeConnRtr 3 } -- officeConnRtr w/Ext WAN SW
ocRtrCx OBJECT IDENTIFIER ::= { officeConnRtr 4 } -- officeConnRtr w/CX SW
ocRtrBa OBJECT IDENTIFIER ::= { officeConnRtr 5 } --officeConnRtr w/Bndry Rtg. SW
ocRtrAr OBJECT IDENTIFIER ::= { officeConnRtr 6 } --officeConnRtr w/AR SW
ocRtrSn OBJECT IDENTIFIER ::= { officeConnRtr 7 } --officeConnRtr w/SNA
ocRtrRb OBJECT IDENTIFIER ::= { officeConnRtr 8 } --officeConnRtr w/RB SW
ocRtrFf OBJECT IDENTIFIER ::= { officeConnRtr 9 } -- officeConnRtr w/FF SW
ocRtrCf OBJECT IDENTIFIER ::= { officeConnRtr 10 }--officeConnRtr w/CF SW
ocRtrBx OBJECT IDENTIFIER ::= { officeConnRtr 11 }--officeConnRtr w/BX SW
ocRtrAppn OBJECT IDENTIFIER ::= { officeConnRtr 12 } -- officeConnRtr w/Appn SW
ocRtrLm OBJECT IDENTIFIER ::= { officeConnRtr 13 } -- officeConnRtr w/Lm Sw
ocRtrLt OBJECT IDENTIFIER ::= { officeConnRtr 14 } -- officeConnRtr w/Lt Sw
ocRtrWm OBJECT IDENTIFIER ::= { officeConnRtr 15 } -- officeConnRtr w/Wm Sw
ocRtrWt OBJECT IDENTIFIER ::= { officeConnRtr 16 } -- officeConnRtr w/Wt Sw
ocRtrAe OBJECT IDENTIFIER ::= { officeConnRtr 17 } -- officeConnRtr w/Ae Sw
ocRtrAp OBJECT IDENTIFIER ::= { officeConnRtr 18 } -- officeConnRtr w/Ap Sw
ocRtrAn OBJECT IDENTIFIER ::= { officeConnRtr 19 } -- officeConnRtr w/An Sw
ocRtrLa OBJECT IDENTIFIER ::= { officeConnRtr 20 } -- officeConnRtr w/La Sw
ocRtrWa OBJECT IDENTIFIER ::= { officeConnRtr 21 } -- officeConnRtr w/Wa Sw
ocRtrAa OBJECT IDENTIFIER ::= { officeConnRtr 22 } -- officeConnRtr w/Aa Sw
ocRtrAb OBJECT IDENTIFIER ::= { officeConnRtr 23 } -- officeConnRtr w/Ab Sw
ocRtrBf OBJECT IDENTIFIER ::= { officeConnRtr 24 } -- officeConnRtr w/Bf Sw
--
-- the following identifiers are assigned to brouterBoards
--
ethernet OBJECT IDENTIFIER ::= { brouterBoards 1 }
fddiPhy OBJECT IDENTIFIER ::= { brouterBoards 2 }
fddiMac OBJECT IDENTIFIER ::= { brouterBoards 3 }
hss OBJECT IDENTIFIER ::= { brouterBoards 4 }
tokenRingBrd OBJECT IDENTIFIER ::= { brouterBoards 5 }
hssG703 OBJECT IDENTIFIER ::= { brouterBoards 6 }
hssRS449 OBJECT IDENTIFIER ::= { brouterBoards 7 }
t3HSSI OBJECT IDENTIFIER ::= { brouterBoards 8 }
dualEth OBJECT IDENTIFIER ::= { brouterBoards 9 }
cec OBJECT IDENTIFIER ::= { brouterBoards 10 }
fddiPhySm OBJECT IDENTIFIER ::= { brouterBoards 11 }
fddiPhyMmSm OBJECT IDENTIFIER ::= { brouterBoards 12 }
fddiPhySmMm OBJECT IDENTIFIER ::= { brouterBoards 13 }
hdwan OBJECT IDENTIFIER ::= { brouterBoards 14 }
hdwan449 OBJECT IDENTIFIER ::= { brouterBoards 15 }
hdwan232 OBJECT IDENTIFIER ::= { brouterBoards 16 }
mp6Eth OBJECT IDENTIFIER ::= { brouterBoards 17 }
trPlus OBJECT IDENTIFIER ::= { brouterBoards 18 }
macPlus OBJECT IDENTIFIER ::= { brouterBoards 19 }
cecStar OBJECT IDENTIFIER ::= { brouterBoards 20 }
isdnBri OBJECT IDENTIFIER ::= { brouterBoards 21 }
isdnPri OBJECT IDENTIFIER ::= { brouterBoards 22 }
mpAtm OBJECT IDENTIFIER ::= { brouterBoards 23 }
hssI431 OBJECT IDENTIFIER ::= { brouterBoards 24 }
mpFddi OBJECT IDENTIFIER ::= { brouterBoards 25 }
mp6EthFl OBJECT IDENTIFIER ::= { brouterBoards 26 }
ethV3 OBJECT IDENTIFIER ::= { brouterBoards 27 }
ethV3Fl OBJECT IDENTIFIER ::= { brouterBoards 28 }
nbroBrd OBJECT IDENTIFIER ::= { brouterBoards 29 }
mpAtmFiber OBJECT IDENTIFIER ::= { brouterBoards 30 }
cec2 OBJECT IDENTIFIER ::= { brouterBoards 31 }
flatFddiMm OBJECT IDENTIFIER ::= { brouterBoards 32 }
flatFddiSs OBJECT IDENTIFIER ::= { brouterBoards 33 }
flatFddiSm OBJECT IDENTIFIER ::= { brouterBoards 34 }
flatFddiMs OBJECT IDENTIFIER ::= { brouterBoards 35 }
--
-- the following identifiers are assigned to brouterBrdFwVers
--
noFw OBJECT IDENTIFIER ::= { brouterBrdFwVers 1 }
cecFw OBJECT IDENTIFIER ::= { brouterBrdFwVers 2 }
hdwanFw OBJECT IDENTIFIER ::= { brouterBrdFwVers 3 }
hdwan232Fw OBJECT IDENTIFIER ::= { brouterBrdFwVers 4 }
hdwan449Fw OBJECT IDENTIFIER ::= { brouterBrdFwVers 5 }
mp6ethFw OBJECT IDENTIFIER ::= { brouterBrdFwVers 6 }
cecStarFw OBJECT IDENTIFIER ::= { brouterBrdFwVers 7 }
mpAtmFw OBJECT IDENTIFIER ::= { brouterBrdFwVers 8 }
mpFddiFw OBJECT IDENTIFIER ::= { brouterBrdFwVers 9 }
mp6EthFlFw OBJECT IDENTIFIER ::= { brouterBrdFwVers 10 }
nbroFw OBJECT IDENTIFIER ::= { brouterBrdFwVers 11 }
--
-- the following identifiers are assigned to brouterBrdSwVers
--
noSw OBJECT IDENTIFIER ::= { brouterBrdSwVers 1 }
mp6eth OBJECT IDENTIFIER ::= { brouterBrdSwVers 2 }
--
-- the following identifiers are assigned under a3Com.products.genericMSWorkstation
--
deskManProduct OBJECT IDENTIFIER ::= { genericMSWorkstation 1 }
--
-- the following identifiers are assigned under a3Com.products.genericMSWorkstation.deskManProduct
--
ethernetSoftHub OBJECT IDENTIFIER ::= { deskManProduct 1 }
ethernetDTAnode OBJECT IDENTIFIER ::= { deskManProduct 2 }
tokenRingSoftHub OBJECT IDENTIFIER ::= { deskManProduct 3 }
tokenRingDTAnode OBJECT IDENTIFIER ::= { deskManProduct 4 }
--
-- the following identifiers are assigned to 3com hubs
--
linkBuilder3GH OBJECT IDENTIFIER ::= { hub 1 }
linkBuilder10BTi OBJECT IDENTIFIER ::= { hub 2 }
linkBuilderECS OBJECT IDENTIFIER ::= { hub 3 }
linkBuilderMSH OBJECT IDENTIFIER ::= { hub 4 }
linkBuilderFMS OBJECT IDENTIFIER ::= { hub 5 }
linkBuilderFddiWorkGroupHub OBJECT IDENTIFIER ::= { hub 6 }
linkBuilderFMSII OBJECT IDENTIFIER ::= { hub 7 }
linkSwitchFMS OBJECT IDENTIFIER ::= { hub 8 }
linkSwitchMSH OBJECT IDENTIFIER ::= { hub 9 }
linkBuilderFMSLBridge OBJECT IDENTIFIER ::= { hub 10 }
linkBuilderTP8i OBJECT IDENTIFIER ::= { hub 11 }
linkBuilderMSHFddi OBJECT IDENTIFIER ::= { hub 12 }
linkSwitch1000 OBJECT IDENTIFIER ::= { hub 13 }
linkSwitch500 OBJECT IDENTIFIER ::= { hub 14 }
linkSwitch2700AU OBJECT IDENTIFIER ::= { hub 15 }
linkSwitch2700Bridge OBJECT IDENTIFIER ::= { hub 16 }
linkBuilderFMS100LBridge OBJECT IDENTIFIER ::= { hub 17 }
linkSwitch2700TliAU OBJECT IDENTIFIER ::= { hub 18 }
linkSwitch2700TliBridge OBJECT IDENTIFIER ::= { hub 19 }
linkBuilderFMS100 OBJECT IDENTIFIER ::= { hub 20 }
officeConnect-Hub8M OBJECT IDENTIFIER ::= { hub 21 }
linkSwitch3000 OBJECT IDENTIFIER ::= { hub 22 }
mshSwitch OBJECT IDENTIFIER ::= { hub 23 }
linkSwitch2000TR OBJECT IDENTIFIER ::= { hub 24 }
oncoreFastModuleFPA100 OBJECT IDENTIFIER ::= { hub 25}
oncoreFastModuleFPA10 OBJECT IDENTIFIER ::= { hub 26}
oncoreFastModuleFPA10FX OBJECT IDENTIFIER ::= { hub 27}
oncoreFastModuleBPA OBJECT IDENTIFIER ::= { hub 28}
superStackDesktopSwitch OBJECT IDENTIFIER ::= { hub 29 }
--
-- the following identifiers are assigned to 3com atm switching products
--
cELLplex7000 OBJECT IDENTIFIER ::= { atm 1 }
cELLplex7000-cards OBJECT IDENTIFIER ::= { atm 2 }
--
-- the following identifiers are assigned to 3com cELLplex7000 interface cards
--
cELLplex-7x00cardBridge OBJECT IDENTIFIER ::= { cELLplex7000-cards 1 }
cELLplex-7200card OBJECT IDENTIFIER ::= { cELLplex7000-cards 2 }
cELLplex-7200Fcard OBJECT IDENTIFIER ::= { cELLplex7000-cards 3 }
cELLplex-7400card OBJECT IDENTIFIER ::= { cELLplex7000-cards 4 }
cELLplex-7600card OBJECT IDENTIFIER ::= { cELLplex7000-cards 5 }
--
-- the following identifiers are assigned to 3com modules and cards
--
linkBuilder3GH-cards OBJECT IDENTIFIER ::= { cards 1 }
linkBuilder10BTi-cards OBJECT IDENTIFIER ::= { cards 2 }
linkBuilderECS-cards OBJECT IDENTIFIER ::= { cards 3 }
linkBuilderMSH-cards OBJECT IDENTIFIER ::= { cards 4 }
linkBuilderFMS-cards OBJECT IDENTIFIER ::= { cards 5 }
linkBuilderFMSII-cards OBJECT IDENTIFIER ::= { cards 6 }
a3C512 OBJECT IDENTIFIER ::= { cards 7 }
linkBuilderTP8i-cards OBJECT IDENTIFIER ::= { cards 8 }
linkSwitch1000-cards OBJECT IDENTIFIER ::= { cards 9 }
linkBuilderFMS100-cards OBJECT IDENTIFIER ::= { cards 10 }
officeConnect-Hub8M-cards OBJECT IDENTIFIER ::= { cards 11 }
linkSwitch2000TR-cards OBJECT IDENTIFIER ::= { cards 12 }
linkBuilder10BTi-cards-utp OBJECT IDENTIFIER ::= { linkBuilder10BTi-cards 1 }
linkBuilder10BT-cards-utp OBJECT IDENTIFIER ::= { linkBuilder10BTi-cards 2 }
linkBuilderFMS-cards-utp OBJECT IDENTIFIER ::= { linkBuilderFMS-cards 1 }
linkBuilderFMS-cards-coax OBJECT IDENTIFIER ::= { linkBuilderFMS-cards 2 }
linkBuilderFMS-cards-fiber OBJECT IDENTIFIER ::= { linkBuilderFMS-cards 3 }
linkBuilderFMS-cards-12fiber OBJECT IDENTIFIER ::= { linkBuilderFMS-cards 4 }
linkBuilderFMS-cards-24utp OBJECT IDENTIFIER ::= { linkBuilderFMS-cards 5 }
linkBuilderFMSII-cards-12tp-rj45 OBJECT IDENTIFIER ::= { linkBuilderFMSII-cards 1 }
linkBuilderFMSII-cards-10coax-bnc OBJECT IDENTIFIER ::= { linkBuilderFMSII-cards 2 }
linkBuilderFMSII-cards-6fiber-st OBJECT IDENTIFIER ::= { linkBuilderFMSII-cards 3 }
linkBuilderFMSII-cards-12fiber-st OBJECT IDENTIFIER ::= { linkBuilderFMSII-cards 4 }
linkBuilderFMSII-cards-24tp-rj45 OBJECT IDENTIFIER ::= { linkBuilderFMSII-cards 5 }
linkBuilderFMSII-cards-24tp-telco OBJECT IDENTIFIER ::= { linkBuilderFMSII-cards 6 }
superStackHub10-cards-12tp-rj45 OBJECT IDENTIFIER ::= { linkBuilderFMSII-cards 7 }
superStackHub10-cards-24tp-rj45 OBJECT IDENTIFIER ::= { linkBuilderFMSII-cards 8 }
superStackHub10-cards-6fiber-st OBJECT IDENTIFIER ::= { linkBuilderFMSII-cards 9 }
superStackHub10-cards-24tp-telco OBJECT IDENTIFIER ::= { linkBuilderFMSII-cards 10 }
a3C512-withBNC-expn-card OBJECT IDENTIFIER ::= { a3C512 1 }
a3C512-withAUI-expn-card OBJECT IDENTIFIER ::= { a3C512 2 }
a3C512-withFOIRL-expn-card OBJECT IDENTIFIER ::= { a3C512 3 }
linkBuilderTP8i-cards-8tp-rj45 OBJECT IDENTIFIER ::= { linkBuilderTP8i-cards 1 }
linkSwitch1000-cards-24tp-rj45 OBJECT IDENTIFIER ::= { linkSwitch1000-cards 1 }
linkSwitch1000-cards-12tp-rj45 OBJECT IDENTIFIER ::= { linkSwitch1000-cards 2 }
linkSwitch3000-cards-5fiber-sc OBJECT IDENTIFIER ::= { linkSwitch1000-cards 3 }
linkSwitch3000-cards-8tp-rj45 OBJECT IDENTIFIER ::= { linkSwitch1000-cards 4 }
superStackSwitch1000-cards-24tp-rj45 OBJECT IDENTIFIER ::= { linkSwitch1000-cards 5 }
superStackSwitch1000-cards-12tp-rj45 OBJECT IDENTIFIER ::= { linkSwitch1000-cards 6 }
superStackSwitch3000-cards-5fiber-sc OBJECT IDENTIFIER ::= { linkSwitch1000-cards 7 }
superStackSwitch3000-cards-8tp-rj45 OBJECT IDENTIFIER ::= { linkSwitch1000-cards 8 }
oncore-cards-5fiber-sc-2tp-rj45-blk OBJECT IDENTIFIER ::= { linkSwitch1000-cards 9}
oncore-cards-24tp-telco-blk OBJECT IDENTIFIER ::= { linkSwitch1000-cards 10 }
oncore-cards-24tp-telco-1fiber-sc-blk OBJECT IDENTIFIER ::= { linkSwitch1000-cards 11}
oncore-cards-1fiber-sc-7blk OBJECT IDENTIFIER ::= { linkSwitch1000-cards 12}
superStackSwitch1000-3000-cards-atm OBJECT IDENTIFIER ::= { linkSwitch1000-cards 13 }
oncore-cards-2fiber-sc-7blk OBJECT IDENTIFIER ::= { linkSwitch1000-cards 14}
oncore-cards-1fiber-sc-tp-rj45-7blk OBJECT IDENTIFIER ::= { linkSwitch1000-cards 15}
oncore-cards-1fiber-sc-atm-7blk OBJECT IDENTIFIER ::= { linkSwitch1000-cards 16}
superStackDesktopSwitch-24tp-rj45 OBJECT IDENTIFIER ::= { linkSwitch1000-cards 17}
linkBuilderFMS100-cards-12utp OBJECT IDENTIFIER ::= { linkBuilderFMS100-cards 1 } -- this is Ethernet 100BaseTX repeater card
linkBuilderFMS100-cards-12T4 OBJECT IDENTIFIER ::= { linkBuilderFMS100-cards 2 } -- this is Ethernet 100BaseT4 repeater card
officeConnect-Hub8M-cards-8tp-rj45 OBJECT IDENTIFIER ::= { officeConnect-Hub8M-cards 1 }
linkSwitch2000TR-cards-12tp-rj45 OBJECT IDENTIFIER ::= { linkSwitch2000TR-cards 1 }
--
-- the following identifiers are assigned to 3com chip sets
--
valcan OBJECT IDENTIFIER ::= { chipSets 1 }
--
-- the following identifiers are assigned to 3com oem products
--
linkConv250 OBJECT IDENTIFIER ::= { oem 1 }
linkConv251 OBJECT IDENTIFIER ::= { oem 2 }
linkConv350 OBJECT IDENTIFIER ::= { oem 3 }
linkConv351 OBJECT IDENTIFIER ::= { oem 4 }
--
-- the following identifiers are assigned to Synernetics products
-- (SysOID 1.3.6.1.4.1.114)
--
synernetics OBJECT IDENTIFIER ::= { enterprises 114 }
lanplex OBJECT IDENTIFIER ::= { synernetics 1 }
lANplex-12-slot-support OBJECT IDENTIFIER ::= { lanplex 1 }
lANplex-4-slot-support OBJECT IDENTIFIER ::= { lanplex 2 }
lpsProducts OBJECT IDENTIFIER ::= { lanplex 3 }
--
-- the following identifiers are assigned to the LANplex product line
--
lps6000 OBJECT IDENTIFIER ::= { lpsProducts 2 }
lps2000 OBJECT IDENTIFIER ::= { lpsProducts 3 }
--
-- the following identifiers are assigned to the LANplex product types
--
lps6012 OBJECT IDENTIFIER ::= { lps6000 1 }
lps6004 OBJECT IDENTIFIER ::= { lps6000 2 }
lps2500 OBJECT IDENTIFIER ::= { lps2000 1 }
lss2200 OBJECT IDENTIFIER ::= { lps2000 2 }
lps2016 OBJECT IDENTIFIER ::= { lps2000 3 }
lss2200SS2 OBJECT IDENTIFIER ::= { lps2000 4 }
--
-- the following identifiers are assigned to the LANplex 6000 devices
--
lps6012System OBJECT IDENTIFIER ::= { lps6012 1 }
lps6012Chassis OBJECT IDENTIFIER ::= { lps6012 2 }
lps6012ESM OBJECT IDENTIFIER ::= { lps6012 3 }
lps6012EFSM OBJECT IDENTIFIER ::= { lps6012 4 }
lps6012TRSM OBJECT IDENTIFIER ::= { lps6012 5 }
lps6012TMM OBJECT IDENTIFIER ::= { lps6012 6 }
lps6012FSM OBJECT IDENTIFIER ::= { lps6012 7 }
lps6004System OBJECT IDENTIFIER ::= { lps6004 1 }
lps6004Chassis OBJECT IDENTIFIER ::= { lps6004 2 }
lps6004ESM OBJECT IDENTIFIER ::= { lps6004 3 }
lps6004EFSM OBJECT IDENTIFIER ::= { lps6004 4 }
lps6004TRSM OBJECT IDENTIFIER ::= { lps6004 5 }
lps6004TMM OBJECT IDENTIFIER ::= { lps6004 6 }
lps6004FSM OBJECT IDENTIFIER ::= { lps6004 7 }
--
-- the following identifiers are assigned to the LANplex agent versions
--
lanplex-2500-2 OBJECT IDENTIFIER ::= { lps2500 2 }
lanplex-2500-3 OBJECT IDENTIFIER ::= { lps2500 3 }
lanplex-2500-4 OBJECT IDENTIFIER ::= { lps2500 4 }
lanplex-2500-5 OBJECT IDENTIFIER ::= { lps2500 5 }
lanplex-2500-6 OBJECT IDENTIFIER ::= { lps2500 6 }
linkSwitch-2200-2 OBJECT IDENTIFIER ::= { lss2200 2 }
linkSwitch-2200-3 OBJECT IDENTIFIER ::= { lss2200 3 }
linkSwitch-2200-4 OBJECT IDENTIFIER ::= { lss2200 4 }
linkSwitch-2200-5 OBJECT IDENTIFIER ::= { lss2200 5 }
linkSwitch-2200-6 OBJECT IDENTIFIER ::= { lss2200 6 }
lanplex-2016-2 OBJECT IDENTIFIER ::= { lps2016 2 }
lanplex-2016-3 OBJECT IDENTIFIER ::= { lps2016 3 }
lanplex-2016-4 OBJECT IDENTIFIER ::= { lps2016 4 }
lanplex-2016-5 OBJECT IDENTIFIER ::= { lps2016 5 }
lanplex-2016-6 OBJECT IDENTIFIER ::= { lps2016 6 }
linkSwitch-2200-SS2-7 OBJECT IDENTIFIER ::= { lss2200SS2 7 }
lanplex-6012-System-2 OBJECT IDENTIFIER ::= { lps6012System 2 }
lanplex-6012-System-3 OBJECT IDENTIFIER ::= { lps6012System 3 }
lanplex-6012-System-4 OBJECT IDENTIFIER ::= { lps6012System 4 }
lanplex-6012-System-5 OBJECT IDENTIFIER ::= { lps6012System 5 }
lanplex-6012-System-6 OBJECT IDENTIFIER ::= { lps6012System 6 }
lanplex-6012-Chassis-2 OBJECT IDENTIFIER ::= { lps6012Chassis 2 }
lanplex-6012-Chassis-3 OBJECT IDENTIFIER ::= { lps6012Chassis 3 }
lanplex-6012-Chassis-4 OBJECT IDENTIFIER ::= { lps6012Chassis 4 }
lanplex-6012-Chassis-5 OBJECT IDENTIFIER ::= { lps6012Chassis 5 }
lanplex-6012-Chassis-6 OBJECT IDENTIFIER ::= { lps6012Chassis 6 }
lanplex-6012-ESM-2 OBJECT IDENTIFIER ::= { lps6012ESM 2 }
lanplex-6012-ESM-3 OBJECT IDENTIFIER ::= { lps6012ESM 3 }
lanplex-6012-ESM-4 OBJECT IDENTIFIER ::= { lps6012ESM 4 }
lanplex-6012-ESM-5 OBJECT IDENTIFIER ::= { lps6012ESM 5 }
lanplex-6012-ESM-6 OBJECT IDENTIFIER ::= { lps6012ESM 6 }
lanplex-6012-EFSM-2 OBJECT IDENTIFIER ::= { lps6012EFSM 2 }
lanplex-6012-EFSM-3 OBJECT IDENTIFIER ::= { lps6012EFSM 3 }
lanplex-6012-EFSM-4 OBJECT IDENTIFIER ::= { lps6012EFSM 4 }
lanplex-6012-EFSM-5 OBJECT IDENTIFIER ::= { lps6012EFSM 5 }
lanplex-6012-EFSM-6 OBJECT IDENTIFIER ::= { lps6012EFSM 6 }
lanplex-6012-TRSM-5 OBJECT IDENTIFIER ::= { lps6012TRSM 5 }
lanplex-6012-TRSM-6 OBJECT IDENTIFIER ::= { lps6012TRSM 6 }
lanplex-6012-TMM-6 OBJECT IDENTIFIER ::= { lps6012TMM 6 }
lanplex-6012-FSM-7 OBJECT IDENTIFIER ::= { lps6012FSM 7 }
lanplex-6004-System-2 OBJECT IDENTIFIER ::= { lps6004System 2 }
lanplex-6004-System-3 OBJECT IDENTIFIER ::= { lps6004System 3 }
lanplex-6004-System-4 OBJECT IDENTIFIER ::= { lps6004System 4 }
lanplex-6004-System-5 OBJECT IDENTIFIER ::= { lps6004System 5 }
lanplex-6004-System-6 OBJECT IDENTIFIER ::= { lps6004System 6 }
lanplex-6004-Chassis-2 OBJECT IDENTIFIER ::= { lps6004Chassis 2 }
lanplex-6004-Chassis-3 OBJECT IDENTIFIER ::= { lps6004Chassis 3 }
lanplex-6004-Chassis-4 OBJECT IDENTIFIER ::= { lps6004Chassis 4 }
lanplex-6004-Chassis-5 OBJECT IDENTIFIER ::= { lps6004Chassis 5 }
lanplex-6004-Chassis-6 OBJECT IDENTIFIER ::= { lps6004Chassis 6 }
lanplex-6004-ESM-2 OBJECT IDENTIFIER ::= { lps6004ESM 2 }
lanplex-6004-ESM-3 OBJECT IDENTIFIER ::= { lps6004ESM 3 }
lanplex-6004-ESM-4 OBJECT IDENTIFIER ::= { lps6004ESM 4 }
lanplex-6004-ESM-5 OBJECT IDENTIFIER ::= { lps6004ESM 5 }
lanplex-6004-ESM-6 OBJECT IDENTIFIER ::= { lps6004ESM 6 }
lanplex-6004-EFSM-2 OBJECT IDENTIFIER ::= { lps6004EFSM 2 }
lanplex-6004-EFSM-3 OBJECT IDENTIFIER ::= { lps6004EFSM 3 }
lanplex-6004-EFSM-4 OBJECT IDENTIFIER ::= { lps6004EFSM 4 }
lanplex-6004-EFSM-5 OBJECT IDENTIFIER ::= { lps6004EFSM 5 }
lanplex-6004-EFSM-6 OBJECT IDENTIFIER ::= { lps6004EFSM 6 }
lanplex-6004-TRSM-5 OBJECT IDENTIFIER ::= { lps6004TRSM 5 }
lanplex-6004-TRSM-6 OBJECT IDENTIFIER ::= { lps6004TRSM 6 }
lanplex-6004-TMM-6 OBJECT IDENTIFIER ::= { lps6004TMM 6 }
lanplex-6004-FSM-7 OBJECT IDENTIFIER ::= { lps6004FSM 7 }
--
-- the following identifier are assigned to the LANplex MIB modules
--
lanplexSystemsMib OBJECT IDENTIFIER ::= { lanplex 4 }
lanplexOptFddi OBJECT IDENTIFIER ::= { lanplex 10 }
--
-- the following identifiers are assigned to Centrum products
-- (SysOID 1.3.6.1.4.1.327)
--
centrum OBJECT IDENTIFIER ::= { enterprises 327 }
mibDoc OBJECT IDENTIFIER ::= { centrum 1 }
centrumRemote OBJECT IDENTIFIER ::= { mibDoc 1 }
--
-- for the older ISOLAN equipment
--
bicc OBJECT IDENTIFIER ::= { enterprises 170 }
bdn OBJECT IDENTIFIER ::= { bicc 1 }
bdnDevices OBJECT IDENTIFIER ::= { bdn 1 }
END
A3COM0017-STACK-CONFIG DEFINITIONS ::= BEGIN
IMPORTS
superStackIIconfig FROM A3COM0004-GENERIC
PhysAddress, DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
;
stackConfiguration OBJECT IDENTIFIER ::= {superStackIIconfig 1}
--
-- This table is used to publicise the units in the stack. The information is
-- represented by a single table, indexed by a simple location index. The
-- convention is that the lower numbered units are at the bottom of the stack.
-- The index will generally NOT be sparse, but management applications CANNOT
-- rely on this. Different technologies can be used to detect stack position
-- and those technologies may or may not detect units that are not powered.
-- Similarly the agents reporting this information are allowed to implement this
-- table in a sparse fashion.
--
-- Note that the position in the stack, and hence the position in this table can
-- change as various units in the stack are switched on and off. Because a unit
-- is indexed in this table as row 2, it should NOT be assumed that unit will
-- continue to remain at location 2. If an application wishes to uniquely tag
-- information for a particular unit in the stack, that unit should be
-- identified by its MAC address.
--
-- Note also that not all values will be available for all units. In this case
-- those objects will be available for those units, but will return default
-- values. Management applications must be aware of this and take appropriate
-- actions.
--
--
--
stackConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF StackConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= {stackConfiguration 1}
stackConfigEntry OBJECT-TYPE
SYNTAX StackConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX {stackUnitLocation}
::= {stackConfigTable 1}
StackConfigEntry ::= SEQUENCE {
stackUnitLocation INTEGER,
stackUnitAddress PhysAddress,
stackUnitLastReset TimeTicks,
stackUnitType INTEGER,
stackUnitDesc DisplayString,
stackUnitName DisplayString (SIZE(0..30)),
stackUnitState INTEGER,
stackUnitManagementType INTEGER,
stackUnitCapabilities OCTET STRING,
stackUnitPromVersion DisplayString,
stackUnitHWVersion DisplayString,
stackUnitSWVersion DisplayString,
stackUnitSerialNumber DisplayString,
stackUnitAttention INTEGER,
stackUnitMgmtInterface INTEGER,
stackUnitSummary OCTET STRING,
stackUnitSlipMgmtInterface INTEGER
}
stackUnitLocation OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Used to identify individual units in the stack. Note that
this value will usually be contiguous, but that gaps may be present due,
for example, to unpowered units."
::= {stackConfigEntry 1}
stackUnitAddress OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "Every conformant unit in the SuperStack II system will have
a unique physical (MAC) address by which it can be recognised. Note
that the location index on this table can change if a unit is inserted
into the stack and so the location can not be used to uniquely identify
a location. Instead an application should refer to units by their
physical address."
::= {stackConfigEntry 2}
stackUnitLastReset OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is the time in hundredths of a second, since this unit
last reset (ie that units concept of sysUpTime). Note that if a unit is
not operational then this object will report zero (0)."
::= {stackConfigEntry 3}
stackUnitType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is an integer type identifier for this unit. The values
of this integer are administered by allocating a MIB object identifier
for each type of unit from a common branch. The value of this object is
then the last level in that identifier. The values are defined in this
MIB module. Note that the values are unlikely to be contiguous.
Note that if a type value is not available for this unit then this
object will return zero. There are several reasons why this value may
not be available through this view of the MIB. One reason may be that
the device is not currently active (dead) or that the information is
only available through the units own agent (see stackUnitManagementType)
."
::= {stackConfigEntry 4}
stackUnitDesc OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is a text string which describes this unit. If a unit
cannot provide a name then the value of this object will be an empty
string."
::= {stackConfigEntry 5}
stackUnitName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
ACCESS read-write
STATUS mandatory
DESCRIPTION "This is a simple text string which can be used by an
application to assign a text name to a unit. By default this string is
empty. If a management application writes a text string to this object
the device will store the string in non-volatile storage."
::= {stackConfigEntry 6}
stackUnitState OBJECT-TYPE
SYNTAX INTEGER {
unitStateUnknown (1),
unitInactive (2),
unitOperational (3),
unitLoading (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object represents the best known state of a unit in the
stack. The unknown state is not expected to be used, but may exist
because of loosely integrated components in the stack. Management
applications MUST EXPECT to see the 'unknown' value. The other states
are as follows:
unitInactive: The device has failed to respond send out periodic update
messages, but it still appears to be in the stack.
unitOperational: The unit is sending our periodic identification
messages and indicates that it is operational, running its complete
image.
unitLoading: The unit is running is a special operational mode which
means that it is unmanaged while it loads a new operational code image.
Note that if the stack ever contains units which can download an
operational image while still being fully managed then this variable
will report 'unitOperational'."
::= {stackConfigEntry 7}
stackUnitManagementType OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
distributed (2),
intelligent (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object can be used to determine the management method
used to access the agent in this unit. The options are:
unknown: The unit has not reported any management capability. It
is either faulty or a non-conformant device.
distributed: This unit can be managed using the SuperStackII
distributed management architecture and so is managed
through this agent. The unit may or may not have an
active comms stack. If it has then the addresses for
that agent can be determined from the address table.
intelligent: The unit has its own SNMP agent which is accessed
seperately. The agent is not part of the SSII
distributed management architecture."
::= {stackConfigEntry 8}
stackUnitCapabilities OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object describes the capabilities of this particular
unit. This is used in conjunction with the upgrade level of the stack
to enable a management application to correctly enable and disable the
various features of the application depending on the capabilities of
the unit.
The object is an octet string, where each octet represents a capability
of the unit. Different capabilities will be added to the list as
required. The current list of values is:
0x01 Full RMON
0x02 3Com Proprietary Resilience MIB
0x03 3Com Repeater Security MIB
0x04 PSHub Port Switching
0x05 PSHub Capability Upgrade Facility
0x06 Dual Speed Hub Capability Upgrade Facility
0x07 TelNet
0x08 Web
0x14 SMA Resource Allocator
0x15 SMA Distributed SNMP
0x16 SMA Global Variables
0x17 SMA Licence Server
0x18 PSHub Cascade Switch
0x19 PSH Load Balancing
So, for example, if a unit has a value of '02 03' for this object then
it supports repeater resilience and security, but no other features
such as RMON."
::= {stackConfigEntry 9}
stackUnitPromVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is the version number of the PROM on the unit. If the
unit has no PROM, does not correctly report the PROM version or is
currently non-operational then this object will return an empty string."
::= {stackConfigEntry 10}
stackUnitHWVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is the hardware version of this unit, expressed as a
string. Note that if the hardware version is not available for this
particular unit then the version string will be empty."
::= {stackConfigEntry 11}
stackUnitSWVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is the software version number of this unit. The
software version number is a string. Note that if a unit does not make
its version number information available, or the unit has no software,
then this object will report an empty string."
::= {stackConfigEntry 12}
stackUnitSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This is the serial number for this unit. The number is
globally unique and expressed as a textual string."
::= {stackConfigEntry 13}
stackUnitAttention OBJECT-TYPE
SYNTAX INTEGER {
noAttention (1),
attention (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Some of the units in the stack will contain a mechanism for
drawing attention to that unit. This is useful for directing
maintainance personnel. The method often employed is for a special LED,
or by placing some other LED into a flashing state. This object gives
access to the attention mechanism for a unit.
Note that if a unit does not support this mechanism then reading the
value of this object will return 'no-such-name' error. The possible
values for an instance of this object which does exist is 'noAttention'
or 'attention'."
::= {stackConfigEntry 14}
stackUnitMgmtInterface OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "If a unit in the stack participates in the distributed
SNMP stack then it will have an instance of this object
(stackUnitManagementType = 'distributed'). The object points to the
entry in the interface table which represents the potential management
interface for this unit. That is the index to use in the extIfTable for
this device. Note that if the value of this object is zero, or the
result of reading this object is NO-SUCH-NAME then there is no
management interface available on that unit."
::= {stackConfigEntry 15}
stackUnitSummary OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object provides a summary of this units configuration
in order to improve the performance of the management applications. The
information in this object is represented as a list of items, each item
is a type-length-value triplet which will have a basic encoding. The
information encoded in this string will be determined by the
requirements of the management applications. It is expected that the
following information will be compressed into this object for a
repeater device:
Unit type Number of ports Array of port information including:
media type, link state, partition state."
::= {stackConfigEntry 16}
stackUnitSlipMgmtInterface OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "If a unit in the stack participates in the distributed
SNMP stack then it will have an instance of this object
(stackUnitManagementType = 'distributed'). The object points to the
entry in the interface table which represents the potential SLIP (serial
port) management interface for this unit. That is the index to use in
the extIfTable for this device. Note that if the value of this object
is zero, or the result of reading this object is NO-SUCH-NAME then
there is no SLIP access port available on that unit."
::= {stackConfigEntry 17}
stackAddressInformation OBJECT IDENTIFIER ::= {superStackIIconfig 2}
stackAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF StackAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This table contains entries for units in the stack which
have active inband communications stacks. The table comprises of a set
of entries for each unit, each entry representing a single address.
Note that the address information in this table cannot be changed!
This table is required specifically for those units which execute their
own SNMP agents without taking part in the Arnie co-operative agent. Ie,
the only devices for which there will be an entry in this table are
those for which the stackUnitManagementType is 'Intelligent'."
::= {stackAddressInformation 1}
stackAddressEntry OBJECT-TYPE
SYNTAX StackAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX {stackUnitLocation, stackAddressNumber}
::= {stackAddressTable 1}
StackAddressEntry ::= SEQUENCE {
stackAddressNumber INTEGER,
stackAddressType INTEGER,
stackAddress OCTET STRING
}
stackAddressNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This identifies one of a number of different addresses for
this unit. This is a second index column for this table, the first
being the unit number shared with the stackConfigTable (stackUnitLocatio
n)."
::= {stackAddressEntry 1}
stackAddressType OBJECT-TYPE
SYNTAX INTEGER {
ipAddress (1),
ipxAddress (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION ""
::= {stackAddressEntry 2}
stackAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION "The address."
::= {stackAddressEntry 3}
-- Define all possible sysObjIdent values as a branch from this MIB. Note that
-- because of the nature of the distributed SNMP architecture it is not possible
-- to determine the function of the device from its sysObjId and so all
-- distributed stack components will have the same value.
--
-- The OBJECT IDENTIFIERS and unit types are now defined in 3Com0025.
--
stackSysObjIdentities OBJECT IDENTIFIER ::= {superStackIIconfig 4}
stackUnitTypes OBJECT IDENTIFIER ::= {superStackIIconfig 5}
END
A3COM0004-GENERIC DEFINITIONS ::= BEGIN
IMPORTS
generic FROM A3Com-products-MIB
OBJECT-TYPE FROM RFC-1212
;
setup OBJECT IDENTIFIER ::= {generic 2}
sysLoader OBJECT IDENTIFIER ::= {generic 3}
security OBJECT IDENTIFIER ::= {generic 4}
gauges OBJECT IDENTIFIER ::= {generic 5}
asciiAgent OBJECT IDENTIFIER ::= {generic 6}
serialIf OBJECT IDENTIFIER ::= {generic 7}
repeaterMgmt OBJECT IDENTIFIER ::= {generic 8}
endStation OBJECT IDENTIFIER ::= {generic 9}
localSnmp OBJECT IDENTIFIER ::= {generic 10}
manager OBJECT IDENTIFIER ::= {generic 11}
unusedGeneric12 OBJECT IDENTIFIER ::= {generic 12}
chassis OBJECT IDENTIFIER ::= {generic 14}
mrmResilience OBJECT IDENTIFIER ::= {generic 15}
tokenRing OBJECT IDENTIFIER ::= {generic 16}
multiRepeater OBJECT IDENTIFIER ::= {generic 17}
bridgeMgmt OBJECT IDENTIFIER ::= {generic 18}
fault OBJECT IDENTIFIER ::= {generic 19}
poll OBJECT IDENTIFIER ::= {generic 20}
powerSupply OBJECT IDENTIFIER ::= {generic 21}
securePort OBJECT IDENTIFIER ::= {generic 22}
alertLed OBJECT IDENTIFIER ::= {generic 23}
remoteControl OBJECT IDENTIFIER ::= {generic 24}
rmonExtensions OBJECT IDENTIFIER ::= {generic 25}
rfc1516extensions OBJECT IDENTIFIER ::= {generic 26}
superStackIIconfig OBJECT IDENTIFIER ::= {generic 27}
extendedIfInfo OBJECT IDENTIFIER ::= {generic 28}
a3ComVlan OBJECT IDENTIFIER ::= {generic 29}
vlanServerClient OBJECT IDENTIFIER ::= {generic 30}
segmentLoadBalancing OBJECT IDENTIFIER ::= {generic 31}
virtualFileSystem OBJECT IDENTIFIER ::= {generic 32}
smartAutosensing OBJECT IDENTIFIER ::= {generic 33}
brasica2 OBJECT IDENTIFIER ::= {generic 34}
smaVlanSupport OBJECT IDENTIFIER ::= {generic 35}
a3ComBridgeExt OBJECT IDENTIFIER ::= {generic 36}
igmpMIB OBJECT IDENTIFIER ::= {generic 37}
mibSummary OBJECT IDENTIFIER ::= {generic 38}
END
- Follow-Ups:
- Re: [ethereal-dev] SNMP Bug Report
- From: Guy Harris
- Re: [ethereal-dev] SNMP Bug Report
- References:
- [ethereal-dev] SNMP Bug Report
- From: Thomas Morin
- [ethereal-dev] SNMP Bug Report
- Prev by Date: [ethereal-dev] SNMP Bug Report
- Next by Date: Re: [ethereal-dev] SNMP Bug Report
- Previous by thread: [ethereal-dev] SNMP Bug Report
- Next by thread: Re: [ethereal-dev] SNMP Bug Report
- Index(es):