Display Filter Reference: Intel Omni-Path SnC - Omni-Path Snoop and Capture MetaData Header

Protocol field name: opa.snc

Versions: 2.2.0 to 3.4.5

Back to Display Filter Reference

Field name Description Type Versions
opa.snc.direction Direction Unsigned integer, 1 byte 2.2.0 to 3.4.5
opa.snc.nobypass Bypass packets not implemented in this version Label 2.2.0 to 3.4.5
opa.snc.pbc.pbccreditreturn Request Credit Return Boolean 2.2.0 to 3.4.5
opa.snc.pbc.pbcdcinfo DC Info Boolean 2.2.0 to 3.4.5
opa.snc.pbc.pbcfecn Set FECN bit Boolean 2.2.0 to 3.4.5
opa.snc.pbc.pbcinsertbypassicrc Insert ICRC for bypass packets Boolean 2.2.0 to 3.4.5
opa.snc.pbc.pbcinserthcrc Insert Hcrc Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.pbc.pbcintr Interrupt Boolean 2.2.0 to 3.4.5
opa.snc.pbc.pbclengthdws pbclengthdws Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.pbc.pbcpacketbypass Packet Type Boolean 2.2.0 to 3.4.5
opa.snc.pbc.pbcstaticratecontrolcnt Static Rate Control Counter Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.pbc.pbctestbadicrc Insert a bad ICRC Boolean 2.2.0 to 3.4.5
opa.snc.pbc.pbctestebp Test End Bad Packet Boolean 2.2.0 to 3.4.5
opa.snc.pbc.pbcvl VL Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.pbc.reserved_21_16 Reserved (6 bits) Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.pbc.reserved_63_48 Reserved (16 bits) Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.portnumber Port Number Unsigned integer, 1 byte 2.2.0 to 3.4.5
opa.snc.reserved16 Reserved (16 bits) Unsigned integer, 2 bytes 2.2.0 to 3.4.5
opa.snc.reserved32 Reserved (32 bits) Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.reserved64 Reserved (64 bits) Unsigned integer, 8 bytes 2.2.0 to 3.4.5
opa.snc.rhf.dcerr End Bad Packet Error Boolean 2.2.0 to 3.4.5
opa.snc.rhf.dcinfo DC Info Boolean 2.2.0 to 3.4.5
opa.snc.rhf.dcuncerr Uncorrectable or parity error Boolean 2.2.0 to 3.4.5
opa.snc.rhf.eccerr Internal memory Uncorrectable error Boolean 2.2.0 to 3.4.5
opa.snc.rhf.egrindex Eager Buffer Index Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.rhf.egroffset Eager Buffer Offset Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.rhf.hdrqoffset Receive Header Offset Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.rhf.icrcerr ICRC error Boolean 2.2.0 to 3.4.5
opa.snc.rhf.khdrlenerr KDETH Length Error Boolean 2.2.0 to 3.4.5
opa.snc.rhf.lenerr Length Error Boolean 2.2.0 to 3.4.5
opa.snc.rhf.pktlen Packet Length Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.rhf.rcvseq Receive Sequence Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.rhf.rcvtype Packet Receive Type Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.rhf.rcvtypeerr Receive Type Error Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.rhf.reserved_62 Reserved (1 bit) Unsigned integer, 4 bytes 2.2.0 to 3.4.5
opa.snc.rhf.tiderr TID Error Boolean 2.2.0 to 3.4.5
opa.snc.rhf.useegrbfr Use Eager Buffer Boolean 2.2.0 to 3.4.5
Go Beyond with Riverbed Technology

Riverbed is Wireshark's primary sponsor and provides our funding. They also make great products that fully integrate with Wireshark.

I have a lot of traffic...

ANSWER: SteelCentral™ AppResponse 11
  • • Full stack analysis – from packets to pages
  • • Rich performance metrics & pre-defined insights for fast problem identification/resolution
  • • Modular, flexible solution for deeply-analyzing network & application performance
Learn More